SU-E-T-521: Dosimetric Effect on Variation of Patient Size in Prostate Volumetric Modulated Arc Therapy.

نویسندگان

  • J Chow
  • R Jiang
چکیده

PURPOSE To evaluate dosimetric variations of planning target volume (PTV) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (VMAT). METHODS Three patients with small (32.0 cm3 ), medium (48.4 cm3 ) and large (86.5 cm3 ) prostate, selected from a group of 30 were planned for prostate VMAT using the 6 MV photon beam. Patient size reduction due to weight loss was modeled by contracting the external body contour with reduced depths (0.5 - 2 cm) in the anterior and both lateral directions. Original normal tissue excluded from the contracted body contour was replaced by air. Dose calculation was repeated with the same planned beam geometry and dose prescription. Dose-volume histograms, dose-volume points of the PTV, clinical target volume (CTV) and critical organs were calculated with variations of reduced depth. RESULTS D99% of the PTV and CTV were found to have increased 2.65 ± 0.03% per cm and 2.75 ± 0.15% per cm of reduced depth in the range of 0.5 and 2 cm. D30% of the rectal wall and bladder increased 2.29 ± 0.12% per cm and 2.31 ± 0.83% per cm, respectively. D5% of the femoral head increased by 3.30 ± 0.11% per cm of reduced depth. Moreover, there was more than 5% increase of minimum, maximum and means doses for the PTV, CTV and critical organs when the reduced depth reached 2 cm. CONCLUSIONS This study provided estimated results of dosimetric changes due to variation of patient size in prostate VMAT. The dosimetric information should help radiation oncology staff to justify changes of dose distribution, when patient weight loss occurs during prostate VMAT. Dose variations of more than 5% were found when the patient's reduced depth was equal to 2 cm. Actual or potential conflicts of interest do not exist.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy

BACKGROUND Volumetric-modulated Dynamic WaveArc therapy (VMDWAT) is a non-coplanar continuous volumetric modulated radiation therapy (VMAT) delivery technique. Here, we monitored mechanical errors and their impact on dose distributions in VMDWAT using logfiles throughout the course of treatment. METHODS Fifteen patients were enrolled (2 skull base tumor patients and 13 prostate cancer patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part18  شماره 

صفحات  -

تاریخ انتشار 2012