Off pump reduction aortoplasty in ascending aortic aneurysm

نویسندگان

  • G Coronella
  • P Pepino
  • E Pezzella
  • A Contaldo
  • R Provenzano
  • P Oliviero
  • S Di Maio
  • V Schiavone
  • S Giordano
  • M Monaco
چکیده

Methods Three patients with a story of ascending aorta aneurysm were selected from October 2012 to December 2012. Trans thoracic echocardiography, angio CT scan and a coronarography were performed during the pre op evaluation. The surgical procedure was performed on beating heart in off pump using a low dose of heparin (5000 UI). A side clamp was used to plicate longitudinally the ascending aorta at the level of maximum dilatation from the sino tubular junction up to the troncus anonymous with controlled hypotension (70 mmHg).The plication was performed with a double layer of 3/0 prolene suture reinforced with two strips of Teflon along the plication. Furthermore, an opened longitudinally 32 mm Dacron tube was wrapped around the ascending aorta and sutured to the plication with a double 3/0 prolene suture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Reduction aortoplasty with external wrapping associated with aortic valve replacement in high-risk patients.

OBJECTIVE To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years). One patient presented severe mitral valve insufficiency. ...

متن کامل

Dissection of Ascending Aorta After Aortic Valve Replacement and Reduction Aortoplasty.

A case of Debakey type-II (Stanford type-A) dissecting aortic aneurysm, after aortic valve replacement and reduction aortoplasty, is reported. The patient was 35 years male who was diagnosed of severe aortic regurgitation along with aortic root dilatation of 7 cm. He underwent aortic valve replacement with 27-ASt Jude's mechanical aortic valve along with reduction aortoplasty. Nine months later...

متن کامل

Alternative Surgical Management of Ascending Aorta Aneurysm

The standard treatment for an ascending aorta aneurysm is radical resection and interposition of a tubular prosthesis. Involvement of other adjacent structures has dictated the employment of more complex surgical techniques. The surgical treatment of concomitant disease of the aortic valve, aortic root and ascending aorta started in 1968 with Bentall and De Bono (Bentall & De Bono, 1968), who a...

متن کامل

Wrapping of an Ascending Aortic Aneurysm with the Multiple Boot-Straps Technique in a Patient Undergoing Off-Pump Coronary Artery Bypass Grafting

Ascending aortic aneurysms are usually treated with graft replacement under cardiopulmonary bypass. However, if a candidate for off-pump coronary artery bypass grafting has an enlarged ascending aorta, surgeons may consider wrapping it without cardiopulmonary bypass. Here, we report a 78-year-old female who underwent successful wrapping of the ascending aorta concomitant with off-pump coronary ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013