A new solar-powered blood pressure measuring device for low-resource settings.
نویسندگان
چکیده
The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermined criteria and to demonstrate the suitability of the device for low resource settings. A device, which fulfilled stipulated criteria in being inexpensive, semiautomated, and solar powered, was validated according to the International Protocol of the European Society of Hypertension; it was then subjected to field testing in 716 subjects from 2 centers in Uganda and 1 in Zambia. The Omron HEM-SOLAR having previously fulfilled accuracy criteria of the International Protocol for both systolic blood pressure (SBP) and diastolic blood pressure (DBP), fulfilled criteria for SBP, but not for DBP, when revalidated. In field testing, average SBPs and DBPs were 120.5 ± 21.6/74.6 ± 13.8 mm Hg and 122.3 ± 21.8/71.2 ± 14.0 mm Hg, respectively, with the auscultatory technique and the Omron HEM-SOLAR, respectively. Between-device agreement in defining SBP was 93.7%. The Omron HEM-SOLAR was favored over the mercury sphygmomanometer by both patients and investigators. In summary, considering the accuracy, robustness, relatively low cost, operational simplicity, and advantages such as solar power, the Omron HEM-SOLAR is likely to be a valuable device for improving BP measurement in low-resource settings with nonphysician health workers.
منابع مشابه
Blood Pressure Measurement Device A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings
Abstract—The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to pre...
متن کاملRecommendations for blood pressure measuring devices for office/clinic use in low resource settings.
This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/clinic use in low resource settings. Blood pressure measuring devices to be used in low resource settings should be accurate, affordable, and easily available worldwide. Given the ser...
متن کاملA low-cost solar-powered blood-pressure device.
It is almost mandatory to label increased blood pressure as a readily detectable and, importantly, preventable contributor to the global epidemic of cardiovascular disease. But there is often little appreciation of the barriers to providing even rudimentary health care in low-to-middle-income countries. A rising tide of hyper tension linked to epidemiological transition in vulnerable urban comm...
متن کاملگزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications
Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...
متن کاملDesign & Implementation of Wireless Sensor Node for Measurement of Conducting Liquid
With abundance of water on the earth the fresh water sources are limited. So a need arises to precisely measure this resource in many industrial and commercial places wirelessly. Many measurement techniques for liquid such as float, pressure gauge, ultrasonic and radar are available. Floats and pressure gauge suffer from cumulative error which increases with time whereas ultrasonic and radar gi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hypertension
دوره 56 6 شماره
صفحات -
تاریخ انتشار 2010