A hydrostatic weighing method using total lung capacity and a small tank.
نویسندگان
چکیده
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool. The three methods included residual volume seated, TLC seated and TLC prone. Eighty male and female subjects were underwater weighed using each of the four methods. Validity coefficients for per cent body fat between the TLC prone (tank) method and the RV seated (pool), TLC seated (pool) and TLC prone (pool) methods were .98, .99 and .99, respectively. A randomised complete block ANOVA found significant differences between the RV seated (pool) method and each of the three TLC methods with respect to both body density and per cent body fat. The differences were negligible with respect to HW error. Reliability of the TLC prone (tank) method was established by weighing twenty subjects three different times with ten-minute time intervals between testing. Multiple correlations yielded reliability coefficients for body density and per cent body fat values of .99 and .99, respectively. It was concluded that the TLC prone (tank) method is valid, reliable and a favourable method of hydrostatic weighing.
منابع مشابه
Hydrostatic Weighing Method Using Total Lung Capacity and a Small Tank
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool....
متن کاملHydrostatic weighing at residual volume and functional residual capacity.
Hydrostatic weighing (HW) was performed at both residual volume (RV) and functional residual capacity (FRC) to determine if underwater weighing at different lung volumes affected the measurement of body density. Subjects were 43 males, 18-25 yr. Subjects were submerged in the prone position, and the lung volume was measured by helium dilution at the time of the underwater weighing. Underwater w...
متن کاملTotal lung capacity, residual volume and predicted residual volume in a densitometric study of older men.
Results of investigations using various lung volumes for hydrostatic weighing determinations (HWD) appear to be inconclusive. Often, these lung volumes are predicted and not clinically determined. For this reason, total lung capacity (TLC), a measured residual volume (RV), and a predicted residual volume (PRV) were used during HWDs to compare the techniques. Twenty-five older men, 56 to 70 year...
متن کاملParametric study of nonlinear buckling capacity of short cylinders with Hemispherical heads under hydrostatic pressure
This study investigates the buckling behavior of short cylindrical shells with hemi-spherical heads subjected to hydrostatic pressure. It is assumed that the length of the cylindrical part is smaller than or equal to its diameter while its material may be dif-ferent from that of hemispherical heads. Finite element analysis was used to seek out the effect of geometric parameters such as thicknes...
متن کاملAn evaluation of a bioelectrical impedance analyser for the estimation of body fat content.
Measurement of body composition is an important part of any assessment of health or fitness. Hydrostatic weighing is generally accepted as the most reliable method for the measurement of body fat content, but is inconvenient. Electrical impedance analysers have recently been proposed as an alternative to the measurement of skinfold thickness. Both these latter methods are convenient, but give v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of sports medicine
دوره 20 1 شماره
صفحات -
تاریخ انتشار 1986