Commissioning of the High Current Ion Sources at the New GSI Injector (HSI)

نویسندگان

  • H. Reich
  • F. Heymach
  • P. Spädtke
چکیده

The new high current injector consisting of an RFQ and an IH structure accepts ions with a mass-to-charge ratio m/q up to 65 with a space charge limit of 0.25 emA m/q. Two types of high current ion sources are used to deliver ion beam currents up to the space charge limit of the RFQ. As a source for ions of gaseous elements a multi cusp ion source (MUCIS) [1] was used. Metallic ions were produced by a metal vapor vacuum arc ion source (MEVVA) [2] [3]. A main concern of the sources is the reliability and the stability of the extracted ion beam. In addition the splitting of the total voltage required to achieve the injection energy of 2.2keV/u (extraction voltage and acceleration voltage) was found to have a strong influence on the beam matching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMMISSIONING OF THE 1.4 MeV/u HIGH CURRENT HEAVY ION LINAC AT GSI

The disassembly of the Unilac prestripper linac of the Wideröe type took place at the beginning of 1999. An increase of more than two orders of magnitude in particle number for the most heavy elements in the SIS had to be gained. Since that time the new High Current Injector (HSI) consisting of H-type RFQ and DTLstructures for dual beam operation was installed and successfully commissioned. The...

متن کامل

High Current Ion Sources for the Fair Accelerator Facility

Vacuum arc ion sources and filament driven multi cusp ion sources are used for the production of high current ion beams of a variety of metallic and gaseous ions at the GSI accelerator facility. For the future project FAIR (Facility of Antiproton and Ion Research) it is foreseen to provide in addition to the existing ion beams a high current proton beam from a separate linear accelerator (plina...

متن کامل

Emittance Measurements at GSI UNILAC

At GSI heavy ion beams are accelerated by the UNIversal Linear ACcelerator UNILAC (see Fig. 1) and the heavy ion synchrotron SIS 18. Heavy ion beams are delivered to the High Current Injector (HSI) from two different ion source terminals: Penning type (PIG) sources for low and MUCIS/ MEVVA type sources for high beam intensities. An RFQ and two IH structures accelerate the ions from 2.2 keV/u up...

متن کامل

The New Gas Stripper and Charge State Separator of the GSI High Current Injector

The GSI Unilac was upgraded as a high current injector for the SIS in 1999. Therefore, the stripping section [1] at 1.4 MeV/u, where a beam transport under highest space charge conditions and multi beam operation had to be established, was completely new designed. Results of the commissioning of the stripper section will be presented. The beam transport to the new gas stripper, and the charge s...

متن کامل

The Low Energy Beam Transport System of the New GSI High Current Injector

The UNILAC was improved for high current performance by replacing the Wideröe prestripper accelerator by an RFQ and an IH-type DTL. In addition, one of two ion source terminals was equipped with high current sources of MUCISand MEVVA-type. Therefore, a redesign of the LEBT from the ion source to the RFQ entrance was necessary. The new LEBT was installed at the beginning of 1999. The commissioni...