Complementary Techniques of Percutaneous Closure of Ductus Arteriosus Using Detachable Cook Coils and Amplatzer Devices.

نویسندگان

  • C A Yuko-Jowi
  • C A Okello
  • L Mutai
چکیده

BACKGROUND Patent Ductus Arteriosus (PDA) is a commoncardiac malformation whose treatment locally has been surgical ligation via a lateral thoracotomy. Device closure of the ductus was first performed at the Mater hospital in 1999 in a ten year old male using a five millilitre detachable cook coil. In 2000 the Amplatzer device was introduced to close larger ducts. Subsequently these devices have been used interchangeably to close both small and large ducts. We report this single centre experience of percutaneous PDA closure in a resource-limited setting; utilising the two techniques. OBJECTIVE To describe our experience of trans-catheter closure of small and large ducts using either the detachable Cook coils or the Amplatzer occluders at the Mater Hospital Nairobi. DESIGN A descriptive retrospective cohort study. Setting: The Mater Hospital, Nairobi, Kenya. SUBJECTS Patients with clinical and echo-cardiographic features of patent ductus arteriosus who underwent cardiac catheterisation and angiography followed by device embolisation of the ductus. RESULTS From April 1999 to October 2009 a total of ninety eight subjects were recruited. into the study. Sixty nine (70%) of these subjects had the ducts closed using the Amplatzer devices, while twenty nine (30%) were embolised using the cook detachable coils. Three of the subjects in the coil group had the ducts embolised using the double technique while the rest were embolised using single coils. Various coil sizes four to eight millimetres were used in patients with small to medium ducts (two to seven millimetres) whereas the Amplatzer duct occluder was successfully used in all the duct sizes. The Amplatzer atrial septal occluder device was used to close very large ducts in two of the patients. The overall success rate was 93.1%, but the coil group had higher failure rate of 6.9% compared to the Amplatzer group of 3%. One patient in the Amplatzer group had a late embolisation requiring surgical retrieval at one month post occlusion. There were no mortalities. CONCLUSION Transcatheter device occlusion of PDA is a safe and alternative to

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness analysis of different devices used for the closure of small-to-medium-sized patent ductus arteriosus in pediatric patients

AIMS In this study, we examined the differences in cost and effectiveness of various devices used for the closure of small to medium sized patent ductus arteriosus (PDA). SETTING AND DESIGN We retrospectively studied 116 patients who underwent closure of small PDAs between January 2010 and January 2015. SUBJECTS AND METHODS Three types of devices were used: the Amplatzer duct occluder (ADO)...

متن کامل

Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

OBJECTIVE To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING Tertiary centres for paediatric cardiology. PATIENTS 71 consecutive patients, aged 1.2-22 years, with a patent ductus a...

متن کامل

Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus

BACKGROUND Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA). Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clini...

متن کامل

Transcatheter Closure of Patent Ductus Arteriosus

Patent ductus arteriosus (PDA) constitutes 6 to 11% of all congenital heart defects. While surgical ligation and video-assisted, thoracoscopic interruption of PDA are still available, transcatheter occlusion of PDAs has recently assumed a major role in closure of PDA. A large number of devices have been designed and tested both in animal models and human subjects, but only few devices (free and...

متن کامل

[Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • East African medical journal

دوره 90 7  شماره 

صفحات  -

تاریخ انتشار 2013