Handling false positives in the genomic era.

نویسنده

  • Ann M Moyer
چکیده

Both procedures used iodinated contrast media, iohexol (Omnipaque 350; GE Healthcare) in this case. The cause of the “floating gel” was an increase in serum density from residual contrast dye still present in the catheter used for the procedures (1 ). Laboratory tests should not be performed, even if the serum is extracted from beneath the gel barrier. The effect of residual dye is unknown, but laboratory results may be falsely low because of dilution with contrast media or be erroneous owing to interference with the assay itself (2, 3 ). This phenomenon can be avoided by properly flushing lines prior to sample collection (4 ) and/or waiting at least 1 half-life (approximately 20 min) before collecting a peripheral blood sample.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Procedure for Screening Expression Libraries for Novel Autoantigens

The standard method for immunoscreening of a cDNA expression library is time-consuming becauseof the production of a large proportion of false positives during the first and second round of screening.This problem is more important when a sensitive chemiluminescence detection system is used. Due tothe high sensitivity of the detection system, there is a need to avoid false posi...

متن کامل

The Development of a Passive False Twister Mechanism in Handling Low Strength Cotton Slivers on High Draft Spinning Machine

A passive false twist unit (spiral) has been developed to assist with the handling lowstrength slivers on a high speed-spinning machine with a high-speed feed. In the first trial, a falsetwist simulator device was constructed to determine whether the passive false twist unit can be usedon high speed feeding with different can distance from the feeding device. In the second trial, theeffects of ...

متن کامل

XVIth QTLMAS: simulated dataset and comparative analysis of submitted results for QTL mapping and genomic evaluation

BACKGROUND A common dataset was simulated and made available to participants of the XVI(th) QTL-MAS workshop. Tasks for the participants were to detect QTLs affecting three traits, to assess their possible pleiotropic effects, and to evaluate the breeding values in a candidate population without phenotypes using genomic information. METHODS Four generations consisting of 20 males and 1000 fem...

متن کامل

Optimal Node Selection and Alarm Exchange Technique for Reducing the Security Cost and False Positives in MANET

Mobile Ad-hoc Network (MANET) is a wireless network consisting of numerous nodes which are move every minute and are highly mobile. Basically, MANET is a self configuring network where nodes can enter the network and also leave the network in a random manner without prior notification to the network. This allows the malicious nodes to enter the network and attack other legitimate node. Hence, t...

متن کامل

Reduction of False Positives using Optimal Node Selection in MANET

Mobile Ad-hoc Network (MANET) is a self configuring network which allows nodes to enter the network and also leave the network in a random manner without notification to the network. This dynamic nature allows the malicious nodes to enter the network and attack other legitimate node. To ensure the security in network it is necessary to detect attacks or malicious nodes and notify the network. I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 58 11  شماره 

صفحات  -

تاریخ انتشار 2012