Comparison of 2-Dimensional, 3-Dimensional, and Surgical Measurements of the Tricuspid Annulus Size: Clinical Implications.

نویسندگان

  • Julien Dreyfus
  • Guillaume Durand-Viel
  • Richard Raffoul
  • Soleiman Alkhoder
  • Ulrik Hvass
  • Costin Radu
  • Nawwar Al-Attar
  • Walid Ghodbhane
  • David Attias
  • Patrick Nataf
  • Alec Vahanian
  • David Messika-Zeitoun
چکیده

BACKGROUND Associated tricuspid annuloplasty is recommended during left-heart valve surgery when the tricuspid annulus (TA) is dilated but methodology for the measurement of TA size and thresholds for TA enlargement are not clearly defined. METHODS AND RESULTS Measurement of the TA diameter (TAD) was prospectively performed using 2-dimensional transthoracic echocardiography (2D-TTE) in 282 patients in 4 different views (parasternal long axis, parasternal short axis, apical 4-chamber [A4C], and subcostal). TAD was also measured using 3D-transesophageal echocardiography in 183 patients (long axis), peroperatively in 120 patients who underwent a tricuspid valve surgery and using TTE (A4C) in 66 healthy volunteers. TAD was significantly different between the 4 2D-TTE views (3.85±0.58, 3.87±0.61, 4.02±0.69, and 3.92±0.65 cm, respectively; P<0.0001) but differences were small and the A4C was the most feasible (76%, 65%, 92%, and 73%, respectively; P<0.0001) and offered the highest reproducibility. TAD measured in A4C view was smaller than when measured by 3D-transesophageal echocardiography (3.90±0.63 versus 4.33±0.62 cm; P<0.0001) but correlation was excellent (r=0.84; P<0.0001) with a systematic 4-mm underestimation. In contrast, 2D-TTE measurements were significantly smaller and only modestly correlated to surgical measurements (4.11±0.61 versus 4.37±0.75 cm; P<0.0001; r=0.57; P<0.0001) which were poorly reproducible. In healthy volunteers, we suggested 42 mm or 23 mm/m(2) as pathological values for the TAD in A4C. CONCLUSIONS Measurements of the TAD using 2D-TTE in A4C were highly feasible and reproducible and despite being systematically smaller than 3D measurements, accurately reflected the degree of TA enlargement as assessed using 3D transesophageal echocardiography. We proposed the thresholds that may be used in future prospective studies to demonstrate whether a preventive strategy would improve the outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

The tricuspid valve annulus: study of size and motion in normal subjects and in patients with tricuspid regurgitation.

The tricuspid valve leaflets and their annular attachments were recorded by two-dimensional echocardiography from a view of the right ventricular inflow tract obtained by placing the transducer at an intermediate position between the left ventricular apex and the left lower sternal border. The transducer was rotated, and recordings were made at 30 degrees rotational intervals around the circumf...

متن کامل

Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?

OBJECTIVES We sought to study the potential role of balloon aortic valvuloplasty (BAV) in sizing the aortic annulus in patients before transcatheter heart valve (THV) implantation. BACKGROUND Despite clinicians' growing experience with THV procedures, the best method of annulus sizing remains unclear. METHODS Twenty-three patients with aortic stenosis (<1.0 cm(2)) who were undergoing surgic...

متن کامل

Calcification of the tricuspid annulus. Case report and review of the relevant literature.

We present a case of tricuspid annulus calcification, documented by fluoroscopy, chest X-ray and cross sectional echocardiography. This case is interesting for two reasons: 1) Tricuspid annulus calcification is extremely rare and very few cases have been reported. 2) It is the third case described where two-dimensional echocardiography established the diagnosis of this very rare condition. Prev...

متن کامل

Surgical management of functional tricuspid regurgitation with a new remodeling annuloplasty ring.

BACKGROUND Moderate-to-severe functional tricuspid regurgitation (TR) should be corrected in patients undergoing surgery for left-sided valvular diseases, to improve long-term outcomes. Several techniques of surgical repair (suture annuloplasty or prosthetic annuloplasty) to correct this condition have been described. Multiple clinical studies have shown the superiority of prosthetic remodeling...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 8 7  شماره 

صفحات  -

تاریخ انتشار 2015