Aorto-Cutaneous Fistula and False Aneurysm of the Ascending Aorta Five Years after its Prosthetic Replacement for Stanford Type A Acute Aortic Dissection.

نویسندگان

  • Pierre Demondion
  • Dorian Verscheure
  • Pascal Leprince
چکیده

Aorto-cutaneous fistula and false aneurysm of the ascending aorta in patients who previously underwent Stanford Type A acute aortic dissection are rare and severe complications. Surgical correction remains a demanding challenge. In a case of false aneurysm rupture during redo sternotomy, selective cannulation of the right axillary and left carotid arteries allowed an efficient method of cerebral perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta

Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...

متن کامل

Surgical Management of Aorto-Esophageal Fistula as a Late Complication after Graft Replacement for Acute Aortic Dissection.

A 49-year-old male presented with chills and a fever. Five years previously, he underwent ascending aorta and aortic arch replacement using the elephant trunk technique for DeBakey type 1 aortic dissection. The preoperative evaluation found an esophago-paraprosthetic fistula between the prosthetic graft and the esophagus. Multiple-stage surgery was performed with appropriate antibiotic and anti...

متن کامل

Giant Aortic Pseudoaneurysm with Stanford Type A Aortic Dissection after Aortic Valve Replacement

Giant pseudoaneurysm of the ascending aorta is a rare but dreadful complication occurring several months or years after aortic surgery. Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture. We present a rare case of giant ascending aneurysm with Stanford type A aortic dissection occurring 6 years after aort...

متن کامل

Modified ‘candy-plug’ technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

BACKGROUND The original 'candy-plug' technique has been reported to be beneficial for the treatment of residual perfused false lumen in patients with aortic dissection. However, this technique is also associated with several problems, such as narrowing of the true lumen and damage to the flap or vessel wall. Therefore, we modified the procedure to overcome these problems. Here we report a case ...

متن کامل

Residual flow in false lumen of chronic descending aortic dissection

A 58-year-old male patient has a history of a Stanford type A aortic dissection running up to the left common iliac artery for which a composite aortic valve graft replacement was performed approximately three years ago. This time, the patient presented with fever and chills. We performed a transesophageal echocardiography (TEE), which excluded vegetations. Upon retracting the TEE probe, the de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aorta

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2017