Standardized Semi-Quantitative Evaluation of [123I]FP-CIT SPECT in a Multicenter Study
نویسندگان
چکیده
Background and Purpose: To the best of our knowledge no multicenter studies have been published using standardized semi-quantitative evaluation of [123I]FP-CIT scan (DAT-SPECT). The aims of this study were: 1) to cross-compare semi-quantitative software-assisted evaluations of DAT-SPECTs performed in three centers with different equipments; 2) to assess the accuracy of semi-quantitative evaluations of DAT-SPECT and 3) to identify the threshold with the best accuracy, sensitivity and specificity in a patient population with suspected parkinsonian syndrome. Materials and Methods: Two hundred twenty patients (mean age at the time of SPECT acquisition, 67.4 ± 9.5 yy) acquired in three centers (Ospedale San Luigi Gonzaga; Ospedale San Giovanni Battista Molinette; Ospedale Mauriziano Umberto I) were included. All of them underwent DAT-SPECT from January 2006 to July 2010. All exams were analyzed with the freely available software BASGAN and semi-quantitative data were used to predict disease. In particular, analyses were based on the values from the most deteriorated putamen and caudate, normalized for age and corrected for equipment. ROC analysis was performed and area under the curve (AUC) was estimated. Results: Analysis showed high AUCs (0.898, 0.864, 0.900 and 0.891 for each center and for the multicenter setting, respectively) confirming the very good accuracies reached. The best cut-off were 0.72 and 0.82 for putamen and caudate respectively. These thresholds allowed sensitivities and specificities in each center and in the multicenter setting of 76% and 96%, 91% and 82%, 93% and 90%, 86% and 89% respectively. No significant differences were observed between sensibility and specificity in each center. Conclusion: A unique threshold useful for all centers with high and similar sensitivities and specificities is possible after correction for age and equipments. The high accuracy reached in this multicenter trial by the semi-quantitative analysis seems similar to accuracies from qualitative analysis in other multicenter studies.
منابع مشابه
Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملClinicopathological and 123I‐FP‐CIT SPECT correlations in patients with dementia
The relationship between clinicopathologic diagnosis and 123I-FP-CIT SPECT in 18 patients with dementia (12 with Lewy body disease) from one center in the United States was assessed. The sensitivity and specificity of abnormal 123I-FP-CIT SPECT with reduced striatal uptake on visual inspection for predicting Lewy body disease were 91.7% and 83.3%, respectively. The mean calculated putamen to oc...
متن کاملValidation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom
Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...
متن کاملDifferent patterns of nigrostriatal degeneration in tremor type versus the akinetic-rigid and mixed types of Parkinson's disease at the early stages: molecular imaging with 123I-FP-CIT SPECT.
The various associations of motor and non-motor symptoms, the onset of motor complications, the cognitive disorder's appearance and other factors make Parkinson's disease (PD) a heterogeneous syndrome with multiple phenotypes. The necessity of discriminating between different forms of PD could have a role in understanding the pathophysiology of extrapyramidal signs with clinical implications. T...
متن کاملImpact of Dopamine Transporter Scan in Parkinson’s Disease
1.1 Technique of nigrostriatal FP-CIT SPECT The density of the presynaptic dopamine reuptake transporters (DAT) can be quantified with [123I]FP-CIT SPECT. The tracer Fluorpropyl-Carbomethoxy-Iodophenyl-Tropan (FPCIT), marked by radioactive 123iodine [123I] (therefore the name [123I]FP-CIT), binds reversibly to the DAT on the presynaptic membrane. Before application of FP-CIT, the iodine uptake ...
متن کامل