Spacer inhalation technique and deposition of extrafine aerosol in asthmatic children.

نویسندگان

  • C M Roller
  • G Zhang
  • R G Troedson
  • C L Leach
  • P N Le Souëf
  • S G Devadason
چکیده

The aim of the present study was to measure airway, oropharyngeal and gastrointestinal deposition of (99m)Tc-labelled hydrofluoroalkane-beclomethasone dipropionate after inhalation via a pressurised metered-dose inhaler and spacer (Aerochamber Plus) in asthmatic children. A group of 24 children (aged 5-17 yrs) with mild asthma inhaled the labelled drug. A total of 12 children took five tidal breaths after each actuation (tidal group). The other 12 children used a slow maximal inhalation followed by a 5 - 10-s breath-hold (breath-hold group). Simultaneous anterior and posterior planar gamma-scintigraphic scans (120-s acquisition) were recorded. For the tidal group, mean+/-sd lung deposition (% ex-actuator, attenuation corrected) was 35.4+/-18.3, 47.5+/-13.0 and 54.9+/-11.2 in patients aged 5-7 (n = 4), 8-10 (n = 4) and 11-17 yrs (n = 4), respectively. Oropharyngeal and gastrointestinal deposition was 24.0+/-10.5, 10.3+/-4.4 and 10.1+/-6.2. With the breath-hold technique, lung deposition was 58.1+/-6.7, 56.6+/-5.2 and 58.4+/-9.2. Oropharyngeal and gastrointestinal deposition was 12.9+/-3.2, 20.1+/-9.5 and 20.8+/-8.8. Inhalation of the extrafine formulation with the breath-hold technique showed significantly improved lung deposition compared with tidal breathing across all ages. Oropharyngeal and gastrointestinal deposition was markedly decreased, regardless of which inhalation technique was applied, compared with a previous paediatric study using the same formulation delivered via a breath-actuated metered-dose inhaler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

متن کامل

Distribution of technetium-99m-labelled QVAR delivered using an Autohaler device in children.

QVAR, an extrafine hydrofluoroalkane/beclomethasone dipropionate formulation, has been shown to double lung deposition in adults. The aim of the present study was to assess the total body deposition and distribution of technetium-99m-labelled (99mTc) QVAR in children after inhalation via an Autohaler. Sixteen male asthmatic children (5-14 yrs) inhaled labelled drug (<4 MBq 99mTc; 100 microg bec...

متن کامل

Improvement of pressurised aerosol deposition with Nebuhaler spacer device.

The effect on aerosol deposition from a pressurised metered dose inhaler of a 750 cm3 spacer device with a one way inhalation valve (Nebuhaler, Astra Pharmaceuticals) was assessed by means of an in vivo radiotracer technique. Nine patients with obstructive lung disease took part in the study. The pattern of deposition associated with use of a metered dose inhaler alone was compared with that ac...

متن کامل

Knowledge of pediatricians in Rio de Janeiro, Brazil, about inhalation therapy in asthmatic children.

BACKGROUND Despite the numerous guidelines on the diagnosis and treatment of asthma, there are data that indicate that general pediatrician's knowledge of the disease and its preferred treatment is limited, which may influence the quality of care given to asthmatic children. The purpose of this study was to describe pediatrician's knowledge of spacers and of concepts of chilhood asthma, as well...

متن کامل

[Aerosol deposition and clinical performance verified with a spacer device made in Brazil]

OBJECTIVE: To assess the lung deposition pattern of radioaerosol and the clinical performance of a spacer developed and made in Brazil. METHODS: Qualitative - in a patient with cystic fibrosis - and semi-quantitative - in two healthy volunteers - assessment of pulmonary deposition of (99)mtechnetium was done using the Aerogama Medical oxigen driven nebulizer system attached to the spacer and a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2007