Exaggerated electrodermal startle responses after intracardiac shock discharges in patients with implanted cardioverter defibrillators.

نویسندگان

  • Karl-Heinz Ladwig
  • Birgitt Marten-Mittag
  • Isabel Deisenhofer
  • Birgit Hofmann
  • Johannes Schapperer
  • Sonja Weyerbrock
  • Claus Schmitt
چکیده

OBJECTIVE We studied whether repetitive intracardiac shock discharges of implantable cardioverter defibrillators (ICDs) provoke an enduring enhancement of startle responses. METHODS The study population comprised 134 patients with an ICD. Among those, 67 patients had experienced shock delivery. Thirty-five patients had received five or more shocks. We used the startle reflex paradigm, which consisted of 15 acoustic stimuli (95 dB, 1000 Hz, 500 ms duration). Skin conductance response was measured using a constant 0.5 V through 8-mm electrodes placed on each subject's nondominant palm. Response magnitude was calculated by subtracting the baseline response level of the 2 seconds immediately preceding tone onset from the maximum response level within 1 to 4 seconds after tone onset. The left orbicularis oculi electromyogram (EMG) response was calculated by subtracting the mean EMG level during the 2 seconds immediately preceding tone onset from the highest EMG level measured within 40 to 200 ms after tone onset. Habituation was defined by the response slope of the regression equation and by the number of trials required to reach the nonresponse criterion. RESULTS Although EMG response measures of magnitude and habituation failed to yield differences between study groups, patients who had experienced five or more ICD shocks exhibited a significantly larger skin conductance response magnitude in comparison to the patients who had experienced fewer than five shocks (median, interquartile range: 0.364, 0.209-0.618 vs. 0.512, 0.375-0.791; Mann-Whitney U test, p =.007). Poorer habituation in the group with five or more shocks in comparison with the low shock group was confirmed both by the number of trials needed to reach the nonresponse criterion (median, interquartile range: 10, 5-14 vs. 5, 2-13; p =.003) and by the response slope (median, interquartile range: 0.209, 0.116-0.274 vs. 0.262, 0.181-0.332; p =.008). After controlling for potential confounding factors (age, anxiety, aversiveness of stimuli, time since last shock experience, and use of beta-adrenoceptor antagonists), intracardiac shock discharges had the strongest impact on augmented skin conductance response magnitude (adjusted odds ratio = 3.0, 95% confidence interval = 1.3-7.2, p =.01) and impaired habituation (adjusted odds ratio = 2.8, 95% confidence interval = 1.2-6.3; p =.015). CONCLUSIONS Intracardiac shock discharges are associated with augmented skin conductance responses and slower habituation, indicating sustained sympathetic arousability, which is presumably centrally mediated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 17 year experience of inappropriate shock therapy in patients with implantable cardioverter-defibrillators: are we getting any better?

I mplantable cardioverter-defibrillators (ICDs) are standard treatment for both secondary and primary prevention in patients with malignant ventricular arrhythmias. 2 Inappropriate shock therapy (IST) occurs in a significant proportion of ICD patients, despite newer generation devices and algorithms specifically employed to try and eliminate this. The frequency of IST in patients implanted with...

متن کامل

Healthcare Utilization and Expenditures Associated With Appropriate and Inappropriate Implantable Defibrillator Shocks.

BACKGROUND In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified. METHODS AND RESULTS We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote ...

متن کامل

Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system.

BACKGROUND Shock delivery of an implantable defibrillator may cause a change in the amplitude of endocardial electrograms and impair the detection of ventricular fibrillation. Thus, the effects of shock discharges on the amplitude of endocardial electrograms were evaluated in five patients undergoing implantation of a cardioverter-defibrillator in combination with a new nonthoracotomy lead syst...

متن کامل

Lead System

Background. Shock delivery of an implantable defibrillator may cause a change in the amplitude of endocardial electrograms and impair the detection of ventricular fibrillation. Thus, the effects of shock discharges on the amplitude of endocardial electrograms were evaluated in five patients undergoing implantation of a cardioverter-defibrillator in combination with a new nonthoracotomy lead sys...

متن کامل

Initial experience with implantation of internal cardioverter/defibrillators under local anaesthesia by electrophysiologists.

This study was designed to evaluate the implantation of internal cardioverter/defibrillators under local anaesthesia by electrophysiologists and to compare this to our former experience of implants with general anaesthesia. Forty-seven internal cardioverter/defibrillators were implanted at our institution by electrophysiologists. Twenty-nine operations were performed under general anaesthesia (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychosomatic medicine

دوره 65 2  شماره 

صفحات  -

تاریخ انتشار 2003