Single-molecule sequence detection via microfluidic planar extensional flow at a stagnation point.

نویسندگان

  • Rebecca Dylla-Spears
  • Jacqueline E Townsend
  • Linda Jen-Jacobson
  • Lydia L Sohn
  • Susan J Muller
چکیده

We demonstrate the use of a microfluidic stagnation point flow to trap and extend single molecules of double-stranded (ds) genomic DNA for detection of target sequences along the DNA backbone. Mutant EcoRI-based fluorescent markers are bound sequence-specifically to fluorescently labeled ds lambda-DNA. The marker-DNA complexes are introduced into a microfluidic cross slot consisting of flow channels that intersect at ninety degrees. Buffered solution containing the marker-DNA complexes flows in one channel of the cross slot, pure buffer flows in the opposing channel at the same flow rate, and fluid exits the two channels at ninety degrees from the inlet channels. This creates a stagnation point at the center of a planar extensional flow, where marker-DNA complexes may be trapped and elongated along the outflow axis. The degree of elongation can be controlled using the flow strength (i.e., a non-dimensional flow rate) in the device. Both the DNA backbone and the markers bound along the stretched DNA are observed directly using fluorescence microscopy, and the location of the markers along the DNA backbone is measured. We find that our method permits detection of each of the five expected target site positions to within 1.5 kb with standard deviations of <1.5 kb. We compare the method's precision and accuracy at molecular extensions of 68% and 88% of the contour length to binding distributions from similar data obtained via molecular combing. We also provide evidence that increased mixing of the sample during binding of the marker to the DNA improves binding to internal target sequences of dsDNA, presumably by extending the DNA and making the internal binding sites more accessible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Stability of Viscoelastic Stagnation Flows in T-shaped Microchannels

We investigate the stability of steady planar stagnation flows of a dilute polyethylene oxide (PEO) solution using T-shaped microchannels. The precise flow rate control and well-defined geometries achievable with microfluidic fabrication technologies enable us to make detailed observations of the onset of elastically-driven flow asymmetries in steady flows with strong planar elongational charac...

متن کامل

Exploring both sequence detection and restriction endonuclease cleavage kinetics by recognition site via single-molecule microfluidic trapping.

We demonstrate the feasibility of a single-molecule microfluidic approach to both sequence detection and obtaining kinetic information for restriction endonucleases on dsDNA. In this method, a microfluidic stagnation point flow is designed to trap, hold, and linearize double-stranded (ds) genomic DNA to which a restriction endonuclease has been pre-bound sequence-specifically. By introducing th...

متن کامل

Molecular Processes Leading to “Necking” in Extensional Flow of Polymer Solutions: Using Microfluidics and Single DNA Imaging

We study the necking and pinch-off dynamics of liquid droplets that contain a semidilute polymer solution of polyacrylamide close to overlap concentration by combining microfluidics and single DNA observation. Polymeric droplets are stretched by passing them through the stagnation point of a T-shaped microfluidic junction. In contrast with the sudden breakup of Newtonian droplets, a stable neck...

متن کامل

Extensional flow of hyaluronic acid solutions in an optimized microfluidic cross-slot device.

We utilize a recently developed microfluidic device, the Optimized Shape Cross-slot Extensional Rheometer (OSCER), to study the elongational flow behavior and rheological properties of hyaluronic acid (HA) solutions representative of the synovial fluid (SF) found in the knee joint. The OSCER geometry is a stagnation point device that imposes a planar extensional flow with a homogenous extension...

متن کامل

Elastic instabilities in planar elongational flow of monodisperse polymer solutions

We investigate purely elastic flow instabilities in the almost ideal planar stagnation point elongational flow field generated by a microfluidic optimized-shape cross-slot extensional rheometer (OSCER). We use time-resolved flow velocimetry and full-field birefringence microscopy to study the behavior of a series of well-characterized viscoelastic polymer solutions under conditions of low fluid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 10 12  شماره 

صفحات  -

تاریخ انتشار 2010