An Electronic Method for Measuring the Fit of Removable Partial Denture Frameworks to Dental Casts

نویسندگان

  • Robert J Williams
  • Zeid Al-Hourani
چکیده

It is well established that the Removable Partial Denture (RPD) is an effective treatment prosthesis. The objectives of a successful RPD are: to preserve the health of remaining oral structure, restore function and restore esthetics. To achieve these objectives, an RPD framework must fit accurately to the supporting structures. This paper presents a method for measuring the gaps or spaces present between the RPD framework and supporting structures which will enable the dentist and the dental technician to evaluate the accuracy of fitting of the prosthesis before it is delivered to the patient. The method used in this research is based on the principle of electric capacitance and uses a specially designed prototype measurement system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying.

Although computer-aided design and manufacture techniques have shown some promising applications in the fabrication of crowns, inlays, and maxillofacial and oral surgery, the field of removable prosthodontics has not embraced these technologies so far. This article describes the development and investigation of computer-aided techniques that may eventually enable prosthodontic procedures such a...

متن کامل

The effect of storage time of removable partial denture wax pattern on the accuracy of fit of the cast framework.

STATEMENT OF PROBLEM Situations may arise in dental laboratories that could result in a time lapse between preparing the wax pattern of the removable partial denture framework and its casting into the cobalt-chromium alloy. PURPOSE This study investigated the effect of storage time of the wax pattern before casting and the influence of the palatal major connector design on the accuracy of its...

متن کامل

The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks

This study explores the application of computer-aided design and manufacture (CAD/ CAM) to the process of electronically surveying a scanned dental cast as a prior stage to producing a sacrificial pattern for a removable partial denture (RPD) metal alloy framework. These are designed to retain artificial replacement teeth in the oral cavity. A cast produced from an impression of a patient’s mou...

متن کامل

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

Effect of Stone Cast Type on Complete Denture Base Adaptation

Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008