Fetal Ductus Venosus Flow Velocity Waveforms and Maternal Serum Afp Transabdominal Chorionic Villus Sampling before and after First-trimester

نویسنده

  • CHRISTOPH BREZINKA
چکیده

Doppler flow velocity waveform recording in the fetal ductus venosus and umbilical artery as well as maternal blood sampling for serum alpha-fetoprotein (MSAFP) was performed before and after transabdominal chorion Mtlus sampling (TACVS) in 36 women of advanced maternal age (3 36 years). Gestational age ranged between 11 and 13 weeks. No chromosomal anomaly was detected. No statistically sigrulicant difference was observed in ductus venosus velocity parameters or in the umbilical artery pulsatility index (PI) before and after C V S in 35 women with a normal pregnancy outcome. One case resulted in fetal loss. Post-CVS median MSAFP levels at 12 weeks (25 kIUA) and 13 weeks (35 k W A ) were significantly higher than pre-CVS levels. In three cases, post-CVS MSAFP levels were higher than 600 kIUA, correlating with feto-maternal transfusions of approximately 1.0-1.4 ml, i.e., of around 40 per cent of feto-placental blood volume. One of these cases displayed absence of fetal peripheral blood flow velocities and fetal bradycardia following TACVS, resulting in fetal loss 1 week later. The remaining two cases had a normal pregnancy outcome, but showed a more than 50 per cent reduction in ductus venosus velocity after TACVS, whereas umbilical artery PI remained unchanged. However, similar velocity changes were associated with only small feto-maternal transfusions. Umbilical artery PI values remained unchanged.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First-trimester screening for chromosomal abnormalities.

There is extensive evidence that effective screening for major chromosomal abnormalities can be provided in the first trimester of pregnancy. Randomized studies have established that the risk of miscarriage from chorionic villus sampling in the first trimester is the same as for amniocentesis in the second trimester. Prospective studies have demonstrated that screening by a combination of fetal...

متن کامل

Prenatal Diagnosis Using Fetal Genetic Material in Maternal Circulation

In the second half of the 20 century, the prenatal diagnosis armamentarium changed dramatically with the introduction of amniocentesis and chorionic villus sampling. Both modalities are, however, invasive techniques and carry a certain risk, albeit low (0.5–1%), of pregnancy loss [1]. Routine noninvasive methods of prenatal diagnosis include firstand second-trimester ultrasonography and materna...

متن کامل

Multicenter study of first-trimester screening for trisomy 21 in 75 821 pregnancies: results and estimation of the potential impact of individual risk-orientated two-stage first-trimester screening.

OBJECTIVES To evaluate the performance of first-trimester screening for trisomy 21 by a combination of maternal age, fetal nuchal translucency (NT) and maternal serum free beta-human chorionic gonadotropin (beta-hCG) and pregnancy-associated plasma protein-A (PAPP-A). In addition, the potential impact of a new individual risk-orientated two-stage approach to first-trimester screening was examin...

متن کامل

Prediction of miscarriage and stillbirth at 11-13 weeks and the contribution of chorionic villus sampling.

OBJECTIVES To derive models for estimating risk of miscarriage and stillbirth from maternal characteristics and findings of first-trimester screening for aneuploidies and to define the procedure-related risk of chorionic villus sampling (CVS) after adjusting for these factors. METHOD We examined 33 856 singleton pregnancies at 11(+0) to 13(+6) weeks, and in 2396 CVS was carried out. Logistic ...

متن کامل

Ductus venosus Doppler in fetuses with cardiac defects and increased nuchal translucency thickness.

OBJECTIVE To examine the possible role of Doppler ultrasound assessment of ductus venosus blood flow in screening for major cardiac defects in chromosomally normal fetuses with increased nuchal translucency (NT) thickness at 11 + 0 to 13 + 6 weeks' gestation. METHODS Ductus venosus blood flow velocity waveforms were obtained immediately before chorionic villus sampling for fetal karyotyping i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005