Harmonic phase-dispersion microscope with a Mach-Zehnder interferometer.
نویسندگان
چکیده
Harmonic phase-dispersion microscopy (PDM) is a new imaging technique in which contrast is provided by differences in refractive index at two harmonically related wavelengths. We report a new configuration of the harmonic phase-dispersion microscope in a Mach-Zehnder geometry as an instrument for imaging biological samples. Several improvements on the earlier design are demonstrated, including a single-pass configuration and acousto-optic modulators for generating the heterodyne signals without mechanical arm scanning. We demonstrate quantitative phase-dispersion images of test structures and biological samples.
منابع مشابه
-
In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...
متن کاملA Review of Optical Routers in Photonic Networks-on-Chip: A Literature Survey
Due to the increasing growth of processing cores in complex computational systems, all the connection converted bottleneck for all systems. With the protection of progressing and constructing complex photonic connection on chip, optical data transmission is the best choice for replacing with electrical interconnection for the reason of gathering connection with a high bandwidth and insertion lo...
متن کاملPhase detection at the quantum limit with multiphoton Mach-Zehnder interferometry.
We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently from the true value of the phase shift and specific assumptions on the noise of the interferometer. We have been able to implement the protocol by using par...
متن کاملNonequilibrium dephasing in an electronic Mach-Zehnder interferometer.
We study nonequilibrium dephasing in an electronic Mach-Zehnder interferometer. We demonstrate that the shot noise at the beam splitter of the interferometer generates an ensemble of nonequilibrium electron density configurations and that electron interactions induce configuration-specific phase shifts of an interfering electron. The resulting dephasing exhibits two characteristic features, a l...
متن کاملSoliton Squeezing in a Mach-Zehnder Fiber Interferometer
A new scheme for generating amplitude squeezed light by means of soliton self-phase modulation is experimentally demonstrated. By injecting 180-fs pulses into an equivalent Mach-Zehnder fiber interferometer, a maximum noise reduction of 4.4± 0.3 dB is obtained (6.3± 0.6 dB when corrected for losses). The dependence of noise reduction on the interferometer splitting ratio and fiber length is stu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 44 7 شماره
صفحات -
تاریخ انتشار 2005