Acetabular liner revision using an anterolateral approach.
نویسندگان
چکیده
Total hip arthroplasty (THA) is recognized as a successful treatment for degenerative hip joint disease. An epidemiological study using the National Hospital Discharge Survey in the United States reported that the number of primary THAs increased from 119,000 in 1990 to 193,000 in 2002. According to nationwide inpatient sample data, the demand for primary THA was estimated to increase from 208,600 in 2005 to 572,000 (174%) in 2030 in the United States. The number of revision THAs in the United States has subsequently increased and is projected to increase from 40,800 in 2005 to 96,700 in 2030. Because revision THAs have a higher incidence of dislocation than primary THAs, preserving the soft tissue, including the gluteus medius muscle, is more necessary at revision THA. However, to our knowledge, few studies have reported soft tissue damage at revision THA. An anterolateral modified Watson-Jones approach, which is between the hip abductor and the tensor fascia lata, preserves the abductor muscles.This article describes 2 cases in which acetabular liner revision was performed through an anterolateral modified Watson-Jones approach. The anterolateral approach provided an excellent surgical field at acetabular liner revision, with no major complications, and has the possibility of being a useful for acetabular liner revision.
منابع مشابه
Isolated acetabular liner exchange compared with complete acetabular component revision in revision of primary uncemented acetabular components: a study of 1649 revisions from the Norwegian Arthroplasty Register.
We analysed the results of different strategies in the revision of primary uncemented acetabular components reported to the Norwegian Arthroplasty Register. The aim was to compare the risk of further acetabular revision after isolated liner exchange and complete component revision. The results of exchanging well-fixed components were also compared with those of exchanging loose acetabular compo...
متن کاملRevision of an acetabular liner has a high risk of dislocation.
Polyethylene liners of modular acetabular components wear sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of revision. We prospectively followed up 1126 Harris-Galante I metal-backed, uncemented components for between nine and 19 years. We found 38 (3.4%) liners of 1126 acetabu...
متن کاملLate liner disassociation of a Pinnacle system acetabular component.
This article describes a case of late locking mechanism failure and disassociation of a Pinnacle acetabular cup (DePuy, Warsaw, Indiana) and Marathon polyethylene liner (DePuy) 53 months after routine primary total hip arthroplasty in an active patient. Following an uncomplicated initial postoperative recovery, the patient felt a pop while kneeling for gardening activities. The patient had no p...
متن کاملMetallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component
The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...
متن کاملCementing polyethylene liners into non-modular acetabular components in revision total hip arthroplasty.
PURPOSE To review mid-term results after replacing the polyethylene liner in a well-fixed acetabular shell. METHODS 22 patients underwent replacement of the polyethylene liner in a well-fixed acetabular shell using cementation. The inner surface of the metal shell was scored with grooves (1 to 2 mm deep) for cement interdigitation. Trial liners were used to assess the appropriate size, with a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2012