A melting-point-of gallium apparatus for thermometer calibration.
نویسندگان
چکیده
We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-temperature plateau can be prolonged for several hours. We have designed a simple automated apparatus that exploits this phenomenon and that permits routine calibration verification of thermistor temperature probes throughout the laboratory day. We describe the physics of the gallium melt, and the design and use of the apparatus.
منابع مشابه
The Nist Industrial Thermometer Calibration Laboratory
The NIST Industrial Thermometer Calibration (ITC) Laboratory provides calibrations of industrial thermometers over the range from –196 °C to 550 °C. The different types of thermometers include liquid-in-glass (LiG), thermistors, thermocouples (<200 °C), and industrial platinum resistance thermometers (IPRTs). Calibrations are performed by both comparison with a standard platinum resistance ther...
متن کاملA New NIST Automated Calibration System for Industrial-Grade Platinum Resistance Thermometers
Industrial-grade platinum resistance thermometers (IPRTs) are calibrated at NIST using a newly automated calibration system. The computer-controlled data-acquisition system is used to calibrate IPRTs over the range from –196 °C to 550 °C using fixed-points (ice point, triple-point of water, and Ga melting point) and comparison baths (cryogenic, water, oil, and salt). A standard platinum resista...
متن کاملThe succinonitrile triple-point standard: a fixed point to improve the accuracy of temperature measurements in the clinical laboratory.
In an investigation of the melting and freezing behavior of succinonitrile, the triple-point temperature was determined to be 58.0805 degrees C, with an estimated uncertainty of +/- 0.0015 degrees C relative to the International Practical Temperature Scale of 1968 (IPTS-68). The triple-point temperature of this material is evaluated as a temperature-fixed point, and some clinical laboratory app...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملStandard Reference Material 1751: Gallium Melting-Point Standard
The melting point of gallium (29.7646 °C) is a defining thermometric fixed point of the International Temperature Scale of 1990 (ITS-90). Realization of this melting point is performed using a fixedpoint cell containing high-purity (≥99.999 99 wt. % pure) gallium. A 30 kg single lot of gallium (99.999 9956 wt. % pure) constituting Standard Reference Material (SRM) 1751 was evaluated, and certif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 8 شماره
صفحات -
تاریخ انتشار 1978