Sandwich assay for tacrolimus using 2 antitacrolimus antibodies.

نویسندگان

  • Tie Q Wei
  • Yi F Zheng
  • Michael Dubowy
  • Manoj Sharma
چکیده

BACKGROUND Although detection of natural haptens by antihapten antibodies in sandwich assay format has the theoretical advantages of high analytical specificity and sensitivity, this type of assay has not been reported because of the seemingly insurmountable task of avoiding steric hindrance between the 2 bindings. This is especially true for ring-structured hydrophobic haptens. The macrolide drug tacrolimus (FK506, Prograf®, 804 Da) is such a hapten. Here we show the detection of tacrolimus using 2 antitacrolimus monoclonal antibodies in a sandwich assay. METHODS Both antibodies were developed by use of an intact tacrolimus molecule covalently linked to a carrier protein but via 2 different positions separated by 10 carbon atoms. Epitope analysis based on drug analog binding was used to show no overlap between the binding sites of the 2 antibodies, indicating the 10-carbon separation resulted in 2 distinct epitopes. The distinct epitopes suggested that the drug might be approachable by the antibodies from 2 separate directions, which predicted simultaneous binding as in sandwich formation. RESULTS This prediction was confirmed in sandwich ELISA and affinity column-mediated immunoassay formats. The assay demonstrated good imprecision and significantly lower metabolite cross-reactivity than competitive assay counterparts. Comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) using 55 whole-blood samples from transplant patients with tacrolimus concentrations ranging from 0.9 to 29.5 ng/mL showed a linear regression: sandwich = 0.99 × LC-MS/MS + 0.10 ng/mL, r = 0.991, Sy|x = 1.08 ng/mL. CONCLUSIONS This work demonstrates that a highly specific sandwich assay using 2 antihapten antibodies is feasible for the measurement of a hapten drug.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tacrolimus measurement: building a better immunoassay.

Tacrolimus (formerly known as FK506) is a macrolide immunosuppressant that is used for primary immunosuppression after organ transplantation (1 ). The landmark work of Starzl at the University of Pittsburgh paved the way for the clinical use of tacrolimus as a primary immunosuppressant, leading to a shift away from cyclosporine use (2– 4 ). Today, tacrolimus is used in the majority of transplan...

متن کامل

Rapid double-sandwich enzyme-linked immunosorbent assay for detection of human immunoglobulin M anti-Toxoplasma gondii antibodies.

The double-sandwich enzyme-linked immunosorbent assay has been compared with the indirect fluorescence assay for the detection of immunoglobulin M antibodies against Toxoplasma gondii in humans. Incubation times have been shortened, permitting the test to be completed within 2 h. The double-sandwich enzyme-linked immunosorbent assay is confirmed to be more sensitive and more specific than the i...

متن کامل

Development of a Quantitative Sandwich Enzyme-Linked Immunosorbent Assay for Detecting the MPT64 Antigen of Mycobacterium tuberculosis

PURPOSE Tuberculosis (TB) is a major infectious disease and is responsible for two million deaths annually. For the identification and quantitation of Mycobacterium tuberculosis (M. tuberculosis), a causative agent of TB, a sandwich enzyme-linked immunosorbent assay (ELISA) against the MPT64 protein of M. tuberculosis, an antigen marker of the M. tuberculosis complex, was developed. MATERIALS...

متن کامل

Development and application of a double-antigen sandwich enzyme-linked immunosorbent assay for detection of antibodies to porcine circovirus 2.

A double-antigen sandwich enzyme-linked immunosorbent assay (ELISA) is described for detection of porcine circovirus 2 (PCV2) antibodies using the well-characterized recombinant PCV2 capsid protein. In a comparative test of 394 pig sera against an indirect immunofluorescence (IIF) test and a commercial ELISA kit (also based on the recombinant PCV2 capsid protein), the results showed that the di...

متن کامل

A simple set of validation steps identifies and removes false results in a sandwich enzyme-linked immunosorbent assay caused by anti-animal IgG antibodies in plasma from arthritis patients

Rheumatoid arthritis (RA) and spondyloarthritis (SpA) are chronic diseases characterized by activation of the immune system and production of antibodies. Thus, rheumatoid factor, anti-animal IgG antibodies and heterophilic antibodies in plasma samples from arthritis patients can interfere with immunoassays such as sandwich enzyme-linked immunosorbent assay (ELISA) systems often used in arthriti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2014