Arterialised earlobe blood gas analysis: an underused technique.

نویسندگان

  • A D Pitkin
  • C M Roberts
  • J A Wedzicha
چکیده

BACKGROUND Techniques for sampling arterialised capillary blood from the finger pulp and the earlobe were first described over two decades ago but, although close agreement between arterial values and earlobe samples has been demonstrated in normal subjects, this technique is not in common usage. METHODS Forty patients with chronic lung disease and a wide range of arterial blood gas values were studied. Simultaneous earlobe and arterial samples were drawn with the patient at rest and analysed in the same blood gas analyser. The respiratory function laboratory staff in 50 UK hospitals with a respiratory department were telephoned and asked whether the technique was used in their hospital and the reasons, if known, for not adopting it. RESULTS Earlobe and arterial blood gas tensions agreed closely over a wide range of values of arterial pH, PCO2 (mean difference 0.21, 95% confidence intervals -0.24 to +0.67 kPa) and PO2 (mean difference -0.17, 95% confidence intervals -1.09 to +0.75 kPa), especially at arterial PO2 values lower than 8 kPa. Of 50 UK centres surveyed 18% used the arterialised earlobe technique and 4% had plans to introduce it. Reasons for not using it were lack of knowledge in 64%, no blood gas analyser in 6%, the technique was considered inaccurate in 4%, and insufficient staff in 4%. CONCLUSIONS Although earlobe blood gas analysis is sufficiently accurate to be reliably substituted for arterial sampling in routine clinical practice, most centres in the UK do not use the technique. The main reasons for this appear to be lack of knowledge of its existence and uncertainty over its accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterialised blood gas sampling in the critically ill: Correct tools for the job?

Sampling from blood has been performed for over 200 years. However clinically useful arterial blood gas sampling became a reality after the development of robust methods for measuring oxygen tension from humans in the 1940s. Thus the development of the Clark electrode and subsequent safe tools for sampling plasma, heralded an era of blood sampling, and analysis from which we have not looked bac...

متن کامل

Prediction of arterial blood gas values from arterialized earlobe blood gas values in patients treated with mechanical ventilation

BACKGROUND/OBJECTIVE Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may sometimes be difficult and cause many complications. Arterialized ear lobe blood samples have been described as adequate to gauge gas exchange in acute and chronically ill pediatric patients. PU...

متن کامل

Earlobe arterialized capillary blood gas analysis in the intensive care unit: a pilot study

BACKGROUND Earlobe arterialized capillary blood gas analysis can be used to estimate arterial gas content and may be suitable for diagnosis and management of critically ill patients. However, its utility and applicability in the ICU setting remains unexplored. METHODS A prospective observational validation study was designed to evaluate this technique in a cohort of mechanically ventilated ad...

متن کامل

Blood gas measurement during exercise: a comparative study between arterialized earlobe sampling and direct arterial puncture in adults.

Sampling arterialized earlobe blood is thought to be easier and less painful than direct arterial puncture, and to allow measurement of blood gas values during exercise without the need to insert an arterial cannula. However, arterialized earlobe oxygen tension (PO2) often underestimates arterial PO2 at rest, and is not fully validated during exercise. We have therefore conducted a prospective ...

متن کامل

Differences in PO2 and PCO2 between arterial and arterialized earlobe samples.

Arterialized ear lobe blood samples have been described as adequate to gauge gas exchange in acute and chronically ill patients. It is a safe procedure, usually performed by medical technicians. We have conducted a prospective study to verify the validity of this method. One hundred and fifteen consecutive adult patients were studied. Blood samples were drawn simultaneously from arterialized ea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 1994