Identifying the sources of the pulse artefact in EEG recordings made inside an MR scanner

نویسندگان

  • Karen J. Mullinger
  • Jade Havenhand
  • Richard Bowtell
چکیده

EEG recordings made during concurrent fMRI are confounded by the pulse artefact (PA), which although smaller than the gradient artefact is often more problematic because of its variability over multiple cardiac cycles. A better understanding of the PA is needed in order to generate improved methods for reducing its effect in EEG-fMRI experiments. Here we performed a study aimed at identifying the relative contributions of three putative sources of the PA (cardiac-pulse-driven head rotation, the Hall effect due to pulsatile blood flow and pulse-driven expansion of the scalp) to its amplitude and variability. EEG recordings were made from 6 subjects lying in a 3T scanner. Accelerometers were fixed on the forehead and temple to monitor head motion. A bite-bar and vacuum cushion were used to restrain the head, thus greatly attenuating the contribution of cardiac-driven head rotation to the PA, while an insulating layer placed between the head and the EEG electrodes was used to eliminate the Hall voltage contribution. Using the root mean square (RMS) amplitude of the PA averaged over leads and time as a measure of the PA amplitude, we found that head restraint and insulating layer reduced the PA by 61% and 42%, respectively, when compared with the PA induced with the subject relaxed, indicating that cardiac-pulse-driven head rotation is the dominant source of the PA. With both the insulating layer and head restraint in place, the PA was reduced in RMS amplitude by 78% compared with the relaxed condition, the remaining PA contribution resulting from scalp expansion or residual head motion. The variance of the PA across cardiac cycles was more strongly reduced by the insulating layer than the head restraint, indicating that the flow-induced Hall voltage makes a larger contribution than pulse-driven head rotation to the variability of the PA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time rejection of gradient and pulse related artefact (GRA and PRA) from electroencephalographic signals recorded during functional magnetic resonance imaging (fMRI)

Electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are two imaging techniques used to study the dynamical activity of the human brain. Although complementary, i.e. EEG has a high temporal resolution while fMRI provides precise volumic information, the simultaneous use of both techniques introduces large artefacts in the EEG recordings. These artefacts are consequences...

متن کامل

Simultaneous EEG/fMRI Phantom Experiments with a Realistic Neuronal Signal

Introduction: Simultaneous EEG/fMRI is hampered by large artefacts produced in the EEG signal by: (i) rapid gradient switching during fMRI acquisition, (ii) the effects of pulsatile blood flow and (iii) subject movement, the latter two of which increase linearly with field strength. One of the most prevalent correction methods for the pulse and gradient artefacts is averaged artefact subtractio...

متن کامل

Removing ballistocardiogram (BCG) artifact from full-scalp EEG acquired inside the MR scanner with Orthogonal Matching Pursuit (OMP)

Ballistocardiogram (BCG) artifact remains a major challenge that renders electroencephalographic (EEG) signals hard to interpret in simultaneous EEG and functional MRI (fMRI) data acquisition. Here, we propose an integrated learning and inference approach that takes advantage of a commercial high-density EEG cap, to estimate the BCG contribution in noisy EEG recordings from inside the MR scanne...

متن کامل

Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction.

Triggering functional MRI (fMRI) image acquisition immediately after an EEG event can provide information on the location of the event generator. However, EEG artifact associated with pulsatile blood flow in a subject inside the scanner may obscure EEG events. This pulse artifact (PA) has been widely recognized as a significant problem, although its characteristics are unpredictable. We have in...

متن کامل

Removal of Pulse Artefact from EEG Data Recorded in MR Environment at 3T. Setting of ICA Parameters for Marking Artefactual Components: Application to Resting-State Data

Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) allow for a non-invasive investigation of cerebral functions with high temporal and spatial resolution. The main challenge of such integration is the removal of the pulse artefact (PA) that affects EEG signals recorded in the magnetic resonance (MR) scanner. Often applied techniques for this purpose are O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 71  شماره 

صفحات  -

تاریخ انتشار 2013