Prescription dose evaluation for APBI with noninvasive image-guided breast brachytherapy using equivalent uniform dose.

نویسندگان

  • Kara Lynne Leonard
  • Mark J Rivard
  • David E Wazer
  • Jessica R Hiatt
  • Shirin Sioshansi
  • Thomas A DiPetrillo
  • Jaroslaw T Hepel
چکیده

PURPOSE Noninvasive image-guided breast brachytherapy (NIBB) is an attractive novel approach to deliver accelerated partial breast irradiation (APBI). Calculations of equivalent uniform dose (EUD) were performed to identify the appropriate APBI dose for this technique. METHODS AND MATERIALS APBI plans were developed for 15 patients: five with three-dimensional conformal APBI (3D-CRT), five with multi-lumen intracavitary balloons (m-IBB), and five simulating NIBB treatment. Prescription doses of 34.0 and 38.5 Gy were delivered in 10 fractions for m-IBB and 3D-CRT, respectively. Prescription doses ranging from 34.0 to 38.5 Gy were considered for NIBB. Dose-volume histogram data from all 3D-CRT, m-IBB, and NIBB plans were used to calculate the biologically effective EUD and corresponding EUD to the PTV_eval using the following equation: EUD = EUBED/(n [1 + EUD/α/β]). An α/β value of 4.6 Gy was assumed for breast tumor. EUD for varying NIBB prescription doses were compared with EUD values for the other APBI techniques. RESULTS Mean PTV_eval volume was largest for 3D-CRT (372.9 cm(3)) and was similar for NIBB and m-IBB (88.7 and 87.2 cm(3), respectively). The EUD value obtained by prescribing 38.5 Gy with 3D-CRT APBI was 38.6 Gy. The EUD value of 34.0 Gy prescribed with m-IBB was 34.4 Gy. EUD values for NIBB ranged from 33.9 to 38.2 Gy for prescription doses ranging from 34.0 to 38.5 Gy. CONCLUSIONS Using EUD calculations to compare APBI techniques and treatment doses, a prescription dose of 36.0 Gy in 10 fractions using NIBB has a comparable biologic equivalent dose to other established brachytherapy techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method

PURPOSE Noninvasive image-guided breast brachytherapy delivers conformal HDR (192)Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accuratel...

متن کامل

The Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

متن کامل

Accelerated partial breast irradiation using the strut-adjusted volume implant single-entry hybrid catheter in brachytherapy for breast cancer in the setting of breast augmentation.

PURPOSE Accelerated partial breast irradiation (APBI) has gained popularity as an alternative to adjuvant whole breast irradiation; however, owing to limitations of delivery devices for brachytherapy, APBI has not been a suitable option for all the patients. This report evaluates APBI using the strut-adjusted volume implant (SAVI) single-entry catheter to deliver brachytherapy for breast cancer...

متن کامل

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2015