Transmission line fault location using hybrid wavelet-Prony method and relief algorithm
نویسندگان
چکیده
Context: Intelligent fault locating in transmission lines consists of three main steps: feature extraction, feature selection, and utilizing a learning tool. Objective: The main objective of this paper is to propose a systematic approach for intelligent fault locating in transmission lines. Method: This paper extracts a group of candidate features by applying a combination of the Wavelet Packet Decomposition (WPD) and Improved Prony Analysis (IPA) methods on single-ended voltage measurements. To have an accurate fault location estimate, useful and efficient features are selected among the candidate features using the regression relief algorithm. In this paper, performances of three regression learning tools including the Generalized Regression Neural Network (GRNN), k-Nearest Neighbor (k-NN) and the Random Forests (RF) in the fault location problem are evaluated and compared, and the best tool is introduced. Results: Numerous training and test patterns are generated through simulation of various fault types in an untransposed transmission line based on different values of fault location, fault resistance, fault inception angle, and magnitude and direction of load current. The results of evaluation using theses patterns show the high efficiency and accuracy of the proposed approach. For various fault types in the test cases, the average values of fault location estimation errors are in the range of 0.153–0.202%. Conclusion: Besides accuracy, the proposed fault locating method is immune against current signal measurement errors and it does not face the problems and costs related to the transmitting and synchronizing data of both line ends. 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Fault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method
In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...
متن کاملFault location and classification in non-homogeneous transmission line utilizing breaker transients
In this paper, a single-ended fault location method is presented based on a circuit breaker operation using the frequencies of traveling waves. The proposed method receives the required data from voltage traveling waves with the aid of Fast Fourier Transform (FFT) and Wavelet Transform. Then, the Artificial Neural Network (ANN) identifies fault type and determines its location. In order to eval...
متن کاملAccurate Fault Classification of Transmission Line Using Wavelet Transform and Probabilistic Neural Network
Fault classification in distance protection of transmission lines, with considering the wide variation in the fault operating conditions, has been very challenging task. This paper presents a probabilistic neural network (PNN) and new feature selection technique for fault classification in transmission lines. Initially, wavelet transform is used for feature extraction from half cycle of post-fa...
متن کاملAccurate Hybrid Method for Rapid Fault Detection, Classification and Location in Transmission Lines using Wavelet Transform and ANNs
The present paper presents an accurate hybrid framework capable to rapidly detect, classify & locate shortcircuit faults on transmission lines. The proposed algorithm has employed the values resulted from each threephase currents wavelet transform in order to obtain instantaneous fault detection. Singling out short-circuit faults based on the measured voltage waveforms and three-phase current i...
متن کاملFault Location on Compensated Transmission Lines without Current Measurement
This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...
متن کامل