Radionuclide assessment of penile corporal venous leak using technetium-99m-labeled red blood cells.

نویسندگان

  • D Groshar
  • S Lidgi
  • A Frenkel
  • Y Vardi
چکیده

In an attempt to evaluate penile corporal venous outflow, a method that utilizes intracorporal injection of Tc-RBC was developed and used in 20 patients with erectile dysfunction. Seven patients showed venous leak and 13 had normal venous outflow. Technetium-labeled RBC corporal clearance in the flaccid state and after intracorporal injection of papaverine (30 mg) and regitine (1 mg) were assessed in sequence by two separate injections of 18.5 MBq of Tc-RBC each. The time for 50% corporal clearance (T50%) was determined from the time activity curves obtained in flaccid state and after intracorporal injection of the vasoactive agent. There were no statistically significant differences in T50% measured in the flaccid state between normal venous outflow (202 +/- 139 sec) and venous leak (92 +/- 35 sec, p = 0.1). However, after intracorporal injection of papaverine and regitine a significant increase in the T50% was noted in normal venous outflow (2892 +/- 1899 sec) as compared to venous leak (213 +/- 123 sec, p less than 0.001). The results suggest that measurement of corporal clearance of Tc-RBC after intracorporal injection of papaverine may be a useful method in detecting venous leak, and could be used as a screening test in patients with erectile dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Application of Technetium-99m-Labeled Red Blood Cells Subcutaneous Radionuclide Venography and Abdominal/Pelvic Hybrid SPECT/CT Imaging in Patients with Suspicion of Proximal Deep Vein Thrombosis

Technetium-99m-labeled red blood cells subcutaneous radionuclide venography can apply to evaluate deep venous flow of lower extremities. We introduce additional abdominal/pelvic hybrid SPECT/CT (single-photon emission computed tomography with computed tomography) to scrutinize the proximal deep venous flow defects in the iliac vein. SPECT/CT imaging is collected when disturbed or asymmetrical i...

متن کامل

Radionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography.

Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. A range of normal values was def...

متن کامل

A case of cavernous hemangioma of the small intestine diagnosed by scintigraphy with Tc-99m-labeled red blood cells.

Hemangioma of the small intestine is rare, and the preoperative diagnosis of it is difficult. We report a patient with gastrointestinal bleeding for whom Tc-99m-labeled red blood cell scintigraphy was useful in diagnosing cavernous hemangioma of the small intestine. A 25-year-old man was referred to our hospital for recurrent iron deficiency anemia. Because of the patient's severe anemia, imagi...

متن کامل

Four patients with gastrointestinal bleeding identified by a modified in vivo technique with labeled red blood cells sedimentation.

OBJECTIVE Gastrointestinal bleeding scintigraphy (GIBS) offers the advantage of continuous monitoring of patients to localize the site of gastrointestinal bleeding. In this study, a modified in vivo labeling method with sedimentation of the labeled red blood cells (RBC) was applied to remove free technetium-99m (99mTc) and increase labeling efficiency. PATIENTS AND METHODS Four patients were ...

متن کامل

Technical Considerations of Tc-99m Labeled Red Blood Cell Scans in the Detection and Localization of Gastrointestinal Bleeding Sites

Arteriography to detect gastrointestinal bleeding, which is often intennittent, is only likely to yield diagnostically useful infonnation if the patient is actively bleeding at a rate of greater than 1.0 cclmin at the time of the procedure. To avoid the unnecessary morbidity of a negative arteriogram we studied Tc-99m in vitro labeled red blood cell (RBC) scintigraphy as a screening test for ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 1992