Whole-brain N-acetylaspartate MR spectroscopic quantification: performance comparison of metabolite versus lipid nulling.

نویسندگان

  • J-B Hövener
  • D J Rigotti
  • M Amann
  • S Liu
  • J S Babb
  • P Bachert
  • A Gass
  • R I Grossman
  • O Gonen
چکیده

BACKGROUND AND PURPOSE Despite the prominent peak of N-acetylaspartate (NAA) in proton MR spectroscopy ((1)H-MR spectroscopy) of the adult brain and its almost exclusive presence in neuronal cells, the total amount of NAA, regarded as their marker, is difficult to obtain due to signal contamination from the skull lipids. This article compares the performance of 2 methods that overcome this difficulty to yield the whole-brain NAA signal, important for the assessment of the total disease load in diffuse neurologic disorders. MATERIALS AND METHODS The heads of 12 healthy volunteers, 3 women and 9 men, 31.0 +/- 7.1 years of age, were scanned at 3T by using 2 nonlocalizing (1)H-MR spectroscopy sequences: One nulls the NAA (TI = 940 ms) every second acquisition by inversion-recovery to cancel the signals of the lipids (T1 << TI) in an add-subtract scheme. The other nulls the signal of the lipids (TI = 155 ms) directly after each acquisition, requiring half as many averages for the same signal-to-noise ratio. Each sequence was repeated 3 times back-to-back on 3 occasions, and the comparison criteria were intrasubject precision (reproducibility) and total measurement duration. RESULTS NAA nulling is nearly twice as precise in its intrinsic back-to-back (5.8% versus 8.6%) as well as longitudinal (10.6% versus 19.7%) coefficients of variation compared with lipid nulling, but at the cost of double the acquisition time. CONCLUSION When speed is a more stringent requirement than precision, the new lipid-nulling sequence is a viable alternative. For precision in cross-sectional or longitudinal global NAA quantification, however, NAA nulling is still the approach of choice despite its x2 ( approximately 5 minutes) time penalty compared with the lipid-nulling approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole-Brain N-Acetylaspartate Quantification: Performance Comparison of NAA Versus Lipid Nulling

Background and Purpose N-acetylaspartate (NAA), the second most abundant amino acid derivative in the mammalian brain, is almost exclusive to neurons and their processes and, therefore, is regarded, as a marker for their health and density. Due to its unique specificity, NAA is the most frequently examined neuro-metabolite and its concentration has been reported to decline in all other central ...

متن کامل

Enhanced axonal metabolism during early natalizumab treatment in relapsing-remitting multiple sclerosis.

BACKGROUND AND PURPOSE The considerable clinical effect of natalizumab in patients with relapsing-remitting multiple sclerosis might be explained by its possible beneficial effect on axonal functioning. In this longitudinal study, the effect of natalizumab on absolute concentrations of total N-acetylaspartate, a marker for neuronal integrity, and other brain metabolites is investigated in patie...

متن کامل

Cerebral N-acetylaspartate is low in patients with multiple sclerosis and abnormal visual evoked potentials.

PURPOSE Our purpose was to compare cerebral proton MR metabolite changes in patients with multiple sclerosis (MS) and abnormal visual evoked potentials (VEPs) with those in MS patients with normal VEPs. METHODS Seventeen subjects with clinically definite MS were studied with VEPs and MR spectroscopic imaging. Proton MR metabolites were measured using a fast spectroscopic imaging technique cal...

متن کامل

Temporal lobe epilepsy: bilateral hippocampal metabolite changes revealed at proton MR spectroscopic imaging.

PURPOSE To determine which proton magnetic resonance (MR) spectroscopic imaging measures are best for lateralizing the seizure focus in patients who have temporal lobe epilepsy with and in those without hippocampal atrophy on MR images, the extent of contralateral abnormalities, and whether there is a correlation between MR spectroscopic imaging findings and surgical outcome. MATERIALS AND ME...

متن کامل

Metabolite findings in tumefactive demyelinating lesions utilizing short echo time proton magnetic resonance spectroscopy.

BACKGROUND AND PURPOSE To use MR spectroscopy to aid in the diagnosis of demyelinating disease and to help differentiate tumefactive demyelinating lesions from neoplastic processes. MATERIALS AND METHODS MR imaging of the brain was obtained in 4 patients who presented clinically with focal neurologic deficits. MR imaging initially revealed parenchymal mass lesions. Single-voxel MR spectroscop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 8  شماره 

صفحات  -

تاریخ انتشار 2008