Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents.

نویسندگان

  • D W Droste
  • J U Kriete
  • J Stypmann
  • M Castrucci
  • T Wichter
  • R Tietje
  • B Weltermann
  • P Young
  • E B Ringelstein
چکیده

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and different provocation procedures. Currently, data on an appropriate time window for the appearance of contrast bubbles in the TCD recording after the injection of the contrast medium and the comparison of different provocation maneuvers to increase right-to-left shunting are insufficient. METHODS Forty-six patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with 6 injection modes was applied in a randomized way: (1) injection of 10 mL of agitated saline without Valsalva maneuver, (2) injection of 10 mL of agitated saline with Valsalva maneuver, (3) injection of 10 mL of a commercial galactose-based contrast agent (Echovist) without Valsalva maneuver, (4) injection of 10 mL of Echovist with Valsalva maneuver, (5) injection of 10 mL of Echovist with standardized Valsalva maneuver, and (6) injection of 10 mL of Echovist with coughing. RESULTS In 20 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt-positive). Sixteen patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 10 patients were only positive on at least 1 TCD investigation but negative during TEE. The amount of microbubbles detected in the various tests decreased in the following order: Echovist and Valsalva maneuver, Echovist with coughing, Echovist and standardized Valsalva maneuver, saline with Valsalva maneuver, Echovist, and saline. With a time window of 20 to 25 seconds for the bubbles to appear in the TCD recording and with a sequence of first Echovist and Valsalva maneuver and then Echovist with coughing, all shunts were reliably identified with a specificity of 65% compared with TEE as the traditional gold standard. The time of first microbubble appearance was not helpful to distinguish between shunts detected on TEE and other shunts. CONCLUSIONS TCD performed twice with 2 provocation maneuvers using Echovist is a sensitive method to identify cardiac right-to-left shunts also identified by TEE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli.

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...

متن کامل

Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts

Background and Purpose—Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Contrast transcranial doppler ultrasound in the detection of right-to-left shunts : time window and threshold in microbubble numbers.

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of contrast agents and a Valsalva maneuver (VM) as provocation procedure. Currently, data on the appropriate timing of the VM, the use of a diagnostic time window, and a threshold in contrast agent microbubbles detected are ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 1999