Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism.

نویسندگان

  • Ayman N Hashem
  • Alaa M El Danasoury
  • Hamed M Anwar
چکیده

PURPOSE To assess axis alignment and stability of the Toric Implantable Collamer Lens (TICL; STAAR Surgical Co) over time. METHODS Thirty-five consecutive eyes of 19 patients received the TICL for treatment of myopic astigmatism. Manifest refraction spherical equivalent (MRSE) and manifest refractive cylinder were measured preoperatively and at 3 months postoperatively. The axis alignment of the TICL was measured using the internal OPD map obtained with the OPD-Scan II (NIDEK Co Ltd). RESULTS Mean refractive cylinder was reduced from 2.80+/-1.45 diopters (D) preoperatively to 0.63+/-0.75 D at 3 months postoperatively; MRSE was -7.61+/-4.02 D preoperatively and -0.14+/-0.38 D at 3 months. Mean absolute value of the measured axis misalignment from baseline (day 1) to 1 month was 2.90+/-2.11 degrees and from 1 month to 3 months was 4.6+/-11.2 degrees. Mean absolute value of the measured changes in axis misalignment from baseline to 3 months was 2.68+/-2.11 degrees (after excluding one eye that required repositioning due to TICL rotation). At 3 months postoperatively, 96.8% (30/31) eyes had <or=8 degrees and 90.3% (28/31) had <or=5 degrees of axis misalignment. CONCLUSIONS The TICL showed minimal axis misalignment after implantation and remained stable 3 months postoperatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism

OBJECTIVES To assess the stability of axis and patient satisfaction after toric visian implantable collamer lens (TICL) implantation for moderate to high myopic astigmatism. METHODS Total 33 eyes of 21 consecutive patients who underwent implantation of TICL for the correction of moderate to high myopic astigmatism were recorded and a minimum follow-up of six months was performed. The deviatio...

متن کامل

Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes

PURPOSE The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. METHODS Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was -4. 98 ± 3.49 ...

متن کامل

JOURNAL OF MEDICAL CASE REPORTS Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...

متن کامل

Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

INTRODUCTION We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. CASE PRESENTATION A 53-year-old woman had undergone toric implan...

متن کامل

Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months.

BACKGROUND The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. METHODS The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 25 10 Suppl  شماره 

صفحات  -

تاریخ انتشار 2009