Successful Ablation of Cavo-tricuspid Isthmus Dependent Atrial Flutter in a Patient with Senning Operation
نویسندگان
چکیده
Correspondence To the Editor: Intraatrial reentry tachycardia (IART) has been reported to occur in 2% to 10% of Mustard and Senning patients at 10 years' follow‑up. We reported a case in which the cavo‑tricuspid isthmus (CTI) in both the systemic venous atrium (SVA) and pulmonary venous atrium (PVA) was necessarily targeted in a patient following Senning operation. The patient was a 26‑year‑old man who was diagnosed d‑transposition of the great arteries and accepted Senning operation at 14 months of age. At the age of 6 years, he underwent permanent pacemaker implantation for sinus bradycardia. In recent 2 years, he developed persistent drug refractory atrial flutter with the highest ventricular rate of 210 beats/min. and was referred for an electrophysiological study and ablation procedure in our center. A 6‑French octapolar deflectable catheter was deployed in the left atrial appendage via the right femoral vein for activation reference. An atrial flutter with a 240 ms tachycardia cycle length (TCL) was recorded. The ostium of the coronary sinus was kept in the PVA in this patient. Thus, the CTI was partitioned in two, with the inferior vena cava (IVC) portion on the SVA and the tricuspid valve (TV) portion on the PVA. Electroanatomic mapping was initiated in the more accessible SVA via right femoral vein access. The activation mapping showed a focal activation pattern with a total activation time <50% of the TCL. The PVA was mapped thereafter. A retrograde access via the femoral artery, aorta, right ventricle, and TV was used. The activation sequence achieved in PVA showed a macroreentry rotating around the TV clockwise. Entrainment pacing at multiple sites around the TV [Figure 1] confirmed the circuit with the postpacing interval approximating the TCL (≤30 ms difference). This patient had developed a significant degree of TV insufficiency, we met great difficulty in stabilizing the catheter when ablating the CTI in PVA, so we tried the transbaffle approach to access the PVA. The transbaffle puncture was made by a transseptal needle which was directed superiorly and anteriorly (12 o'clock). The needle traversed into the PVA through the superior portion of the baffle limb [Figure 2], an 8.5‑French sheath was then advanced in the PVA through a guidewire. A linear radiofrequency (RF) lesion bridging the large scar area on the free wall of the PVA to the tricuspid annulus terminated the tachycardia. A 20‑electrode mapping catheter (Halo, Biosense Webster, Inc.) was positioned in …
منابع مشابه
Voltage-directed cavo-tricuspid isthmus ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I patient
A successful case of maximum voltage-directed cavo-tricuspid isthmus (CTI) ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I (DM1) patient is reported. The patient complained recurrent episodes of atrial flutter, revealed by the atrio-ventricular electrograms analysis during the routine pacemaker controls.
متن کاملCardiogenic Shock, Acute Severe Mitral Regurgitation and Complete Heart Block After Cavo-Tricuspid Isthmus Atrial Flutter Ablation
Radiofrequency (RF) ablation is the first-line management of cavo-tricuspid isthmus dependent atrial flutter. It has been performed with 95% success rate. Adverse events are very rare. We report the first case of acute severe mitral regurgitation (MR) and complete heart block developed after successful atrial flutter ablation. A 62-year-old female with mild MR presented with palpitations. Surfa...
متن کاملWhat is behind radiofrequency delivery at the cavo-tricuspid isthmus?
Catheter-based ablation of isthmus-dependent common atrial flutter results in very high success rates and almost no complications. However, bidirectional conduction block through the isthmus may be challenging in a small percentage of patients regarding the use of high power and high temperature settings during radiofrequency delivery. Anatomical and physiological circumstances may be the reaso...
متن کاملIMAGE IN CARDIOLOGY What is behind radiofrequency delivery at the cavo-tricuspid isthmus?
Catheter-based ablation of isthmus-dependent common atrial flutter results in very high success rates and almost no complications. However, bidirectional conduction block through the isthmus may be challenging in a small percentage of patients regarding the use of high power and high temperature settings during radiofrequency delivery. Anatomical and physiological circumstances may be the reaso...
متن کاملCavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter.
AIMS A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl). M...
متن کامل