Prevention of hemodialysis catheter-related bloodstream infection using an antimicrobial lock.
نویسندگان
چکیده
Among currently available vascular access options for hemodialysis, central venous catheters show the poorest reliability, with frequent complications of thrombosis and stenosis impairing patency. The most serious problem, however, is catheter-related bloodstream infection (CRBI), which is typically a cause for removal of the catheter and protracted systemic antibiotic therapy. In our experience, a totally implanted device (Dialock, Biolink Corp.) seems to confer a better global protection against catheter-related infections than standard tunneled catheters, accounting for 0.97 vs. 4.75 infection episodes/1,000 catheter-days, respectively (p < 0.001). Bloodstream infection rates, however, are not statistically different in the two groups (0.85 vs. 0.81 per 1,000 catheter-days; p = n.s.), indicating that the improvement is mainly related to local cutaneous infections. On the other hand, in the Sodemann experience, a new taurolidine-based lock solution (Neutrolin, Biolink Corp.) greatly reduced CRBI rates with both subcutaneous ports and tunneled catheters to 0.29 and 0.20 episodes/1,000 catheter-days, respectively. These promising results await further confirmation from ongoing clinical trials.
منابع مشابه
A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomized trial.
BACKGROUND AND PURPOSE Catheter-related bloodstream infection is the greatest threat to the safety of patients on hemodialysis. Catheter lock solutions containing heparin have been linked to an increased risk of hemorrhage and thrombocytopenia. OBJECTIVES To ascertain the safety and efficacy for prevention of catheter-related bloodstream infection and catheter loss from patency failure of a n...
متن کاملIs Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis
Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...
متن کاملPrevention of catheter-related bloodstream infections in patients on hemodialysis: challenges and management strategies.
Catheter-related bloodstream infections are a significant source of morbidity and mortality in the end-stage renal disease population. Although alternative accesses to undergoing renal replacement therapy exist, many patients begin hemodialysis with a dialysis catheter due to logistic and physiologic factors involved in arteriovenous fistula creation and maturation. Colonization of catheters vi...
متن کاملRisk of catheter-related bloodstream infection in elderly patients on hemodialysis.
BACKGROUND AND OBJECTIVES Elderly patients require tunneled central vein dialysis catheters more often than younger patients. Little is known about the risk of catheter-related bloodstream infection in this population. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS This study identified 464 patients on hemodialysis with tunneled central vein dialysis catheters between 2005 and 2007 and exclude...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood purification
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2002