Wire tomography in the H-1NF heliac for investigation of fine structure of magnetic islands.

نویسندگان

  • Santhosh T A Kumar
  • Boyd D Blackwell
  • Jeffrey H Harris
چکیده

Electron beam wire tomography in the H-1NF heliac enables high resolution mapping of vacuum flux surfaces with minimal disruption of the plasma operations schedule. Recent experimental results have proven this technique to be a highly accurate and high resolution method for mapping vacuum magnetic islands. Islands of width as small as delta approximately 8 mm have been measured, providing estimates of the internal rotational transform of the island. Point-to-point comparison of the mapping results with computer tracing, in conjunction with an image warping technique, enables systematic exploration of magnetic islands and surfaces of interest. Recent development of a fast mapping technique significantly reduced the mapping time and made this technique suitable for mapping at higher magnetic fields. This article presents recent experimental results and associated techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of error field sources by accurate mapping of the magnetic geometry of the H-1 heliac

High precision mapping of the vacuum flux surfaces of the H-1NF heliac is carried out using electron-beam multiwire tomography for various magnetic configurations and field strengths. The extreme accuracy of this technique has been exploited to understand the nature of error fields and to determine the best-fit empirical values for the H-1NF coil parameters, by point-by-point matching experimen...

متن کامل

Studies of resonantly produced plasmas in the H-1NF heliac using a far-infrared scanning interferometer

The H-1NF heliac regularly operates using the ion cyclotron range of frequencies at 0.5 T to produce plasmas with a mixture of hydrogen and helium gases. Due to the complex three-dimensional structure of the magnetic flux surfaces, these plasmas require sophisticated diagnostic systems, with good spatial coverage, to extract meaningful physical information. This article presents a study of the ...

متن کامل

Configurational Effects on Stability and Confinement in the H-1NF Heliac

H-1 is a helical axis stellarator of major radius R=1m, and average minor radius ~ 0.150.2 m. Its flexible heliac coil set permits access to a wide range of magnetic configurations. RFgenerated plasma shows a very complex dependence on configuration of both the electron density and the nature of fluctuations. Magnetic fluctuations range from highly coherent, often multi-frequency in sequenc...

متن کامل

A multichannel magnetic probe system for analysing magnetic fluctuations in helical axis plasmas.

The need to understand the structure of magnetic fluctuations in H-1NF heliac [S. Hamberger et al., Fusion Technol. 17, 123 (1990)] plasmas has motivated the installation of a sixteen former, tri-axis helical magnetic probe Mirnov array (HMA). The new array complements two existing poloidal Mirnov arrays by providing polarisation information, higher frequency response, and improved toroidal res...

متن کامل

High-resolution tomographic imaging of vacuum magnetic surfaces in the H-1 heliac

A new, high-precision rotating wire grid apparatus for vacuum magnetic surface mapping of current-free toroidal plasma confinement geometries is described. This full-scaled version of the prototype apparatus developed on the SHEILA heliac has been tested and permanently installed on the H-1 heliac. Data of high quality are obtained with low electron energy ~,20 eV! to avoid drift errors, with s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 2007