Use of an implantable monitor to detect arrhythmia recurrences and select patients for early repeat catheter ablation for atrial fibrillation: a pilot study.

نویسندگان

  • Evgeny Pokushalov
  • Alexander Romanov
  • Giorgio Corbucci
  • Sergey Artyomenko
  • Alex Turov
  • Natalya Shirokova
  • Alexander Karaskov
چکیده

BACKGROUND Catheter ablation of atrial fibrillation (AF) has proved effective in curing highly symptomatic patients with paroxysmal AF. The aim of this prospective, randomized study was to identify the optimal treatment of patients with AF recurrences after the first ablation. METHODS AND RESULTS Two hundred eighty-six patients with paroxysmal AF underwent ablation (circumferential pulmonary vein isolation with linear lesions) and were monitored with an implantable cardiac monitor (Reveal XT, Medtronic). Patients without AF recurrences during the 3-month postablation period were assigned to group 1; those with AF recurrences to group 2. Patients in group 2 were randomly assigned to group 3 or group 4. Group 3 patients were treated only with antiarrhythmic drugs for 6 weeks, with no early reablation during the 3-month postablation period. In the case of AF recurrence after the 3-month postablation period, patients underwent reablation. Group 4 patients were treated according to the onset mechanism of AF recurrences, as detected and stored by the implantable cardiac monitor: antiarrhythmic drug therapy, but no reablation if AF was not preceded by triggers; early reablation if premature atrial beats or atrial tachycardias or flutter triggered AF. All patients were followed up for 1 year to assess maintenance of sinus rhythm in each group. On 12-month follow-up examination, of the 119 (42%) patients in group 1, 112 (94%) had no AF recurrences. Among the 83 patients in group 3, only 27 (33%) had no recurrences. Of the 84 group 4 patients, 67 (80%) had no AF recurrences (P<0.0001 versus group 3). CONCLUSIONS Patients with recurrences after the first AF ablation are likely to respond to a second early ablation when AF is triggered by supraventricular arrhythmias or premature contractions. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01164319.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

The APPLE Score – A Novel Score for the Prediction of Rhythm Outcomes after Repeat Catheter Ablation of Atrial Fibrillation

BACKGROUND Arrhythmia recurrences after catheter ablation occur in up to 50% within one year but their prediction remains challenging. Recently, we developed a novel score for the prediction of rhythm outcomes after single AF ablation demonstrating superiority to other scores. The current study was performed to 1) prove the predictive value of the APPLE score in patients undergoing repeat AF ab...

متن کامل

Long-term Success and Follow-up After Atrial Fibrillation Ablation

Atrial fibrillation (AF) is the most prevalent sustained arrhythmia in clinical practice. It is associated with significant morbidity and mortality and has been identified as an independent risk factor for ischemic stroke and thromboembolic events. Catheter ablation has become an established rhythm control therapy in patients with highly symptomatic drug-refractory AF. The definition of ablatio...

متن کامل

How To Follow Atrial Fibrillation Ablation Patients?

Catheter ablation is an established treatment option for symptomatic atrial fibrillation (AF), with circumferential pulmonary vein isolation being considered the cornerstone of the procedure. However, this is a complex intervention with potential major complications and with common arrhythmia recurrences. There is consensus among experts that all patients should be seen in follow-up regularly a...

متن کامل

Monitoring Atrial Fibrillation After Catheter Ablation.

Although catheter ablation is an effective treatment for recurrent atrial fibrillation (AF), there is no consensus on the definition of success or follow-up strategies. Symptoms are the major motivation for undergoing catheter ablation in patients with AF, however it is well known that reliance on perception of AF by patients after AF ablation results in an underestimation of recurrence of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 2011