Regional myocardial perfusion reserve determined using myocardial perfusion magnetic resonance imaging showed a direct correlation with coronary flow velocity reserve by Doppler flow wire.
نویسندگان
چکیده
AIMS Quantitative analysis of rest-stress myocardial perfusion magnetic resonance imaging (MRI) can provide assessments of regional myocardial perfusion reserve (MPR). The purpose of this study was to compare regional MPR determined by myocardial perfusion MRI with coronary flow reserve (CFR) by intracoronary Doppler flow wire. METHODS AND RESULTS Twenty patients with suspected coronary artery disease (CAD) were studied. Average peak velocity was measured by Doppler flow wire in the resting state and during adenosine triphosphate (ATP) stress in 36 coronary arteries. CFR measurements for each patient were performed in the culprit and one non-culprit non-stenotic artery. First-pass, contrast-enhanced myocardial perfusion MR images were obtained in the resting state and during ATP stress within the week before the Doppler wire procedure. Regional myocardial blood flow (MBF) was quantified in 16 myocardial segments by analysing arterial input and myocardial output using a Patlak plot method. MPR was calculated as stress MBF divided by rest MBF. CFR measured by Doppler flow wire was compared with MPR in the myocardial segments corresponding to vessel territories. The average MPR measured by perfusion MRI was 1.77 +/- 0.62 for the culprit arteries and 3.45 +/- 0.78 for the non-culprit arteries, respectively (P < 0.001). The averaged CFR by Doppler flow wire was 1.72 +/- 0.44 in the culprit arteries and 3.14 +/- 0.74 in the non-culprit arteries, respectively (P < 0.001). For both culprit and non-culprit vessel groups, significant direct correlations were observed between MR assessments of MPR and Doppler assessments of CFR (culprit artery: R = 0.87, Non-culprit artery: R = 0.86) On Bland-Altman analysis, the mean differences between MPR determined by myocardial perfusion MRI and CFR measured by Doppler wire were 0.05 in culprit arteries (95% limit of agreement; -0.65 to 0.56) and 0.36 in non-culprit arteries (95% limit of agreement; -1.24 to 0.44). The sensitivity and specificity of MR measurement of MPR for predicting physiologically significant reduction of Doppler CFR (<2) was 88% (95% CI 61.7-98.5) and 90% (95% CI 68.3-98.8), respectively. CONCLUSION The current results using Doppler flow wire as a reference method demonstrated that quantitative analysis of stress-rest myocardial perfusion MRI can provide a non-invasive assessment of reduced MPR in patients with CAD.
منابع مشابه
Magnetic Resonance for Noninvasive Detection of Microcirculatory Disease Associated With Allograft Vasculopathy: Intracoronary Measurement Validation.
INTRODUCTION AND OBJECTIVES Cardiac allograft vasculopathy affects both epicardial and microcirculatory coronary compartments. Magnetic resonance perfusion imaging has been proposed as a useful tool to assess microcirculation mostly outside the heart transplantation setting. Instantaneous hyperemic diastolic flow velocity-pressure slope, an intracoronary physiology index, has demonstrated a bet...
متن کاملVasodilator response assessment in porcine myocardium with magnetic resonance relaxometry.
BACKGROUND This research describes an early preclinical study of the biophysical mechanisms governing changes in myocardial T2 during vasodilation in normal myocardium. METHODS AND RESULTS Theoretical modeling and experimental studies in an instrumented pig model (n=7) provided measures of changes in myocardial T2, relative blood volume (BV), and microcirculation oxygen levels (%O2) during in...
متن کاملCorrelation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کامل2150 Correlation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کاملCorrelation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2009