Ophthalmoscopic-Perspectively Distorted Optic Disc Diameters and Real Disc Diameters.

نویسندگان

  • Yi Dai
  • Jost B Jonas
  • Zhihong Ling
  • Xinghuai Sun
چکیده

PURPOSE To investigate the difference between two-dimensionally measured disc diameters (DDs) based on fundus images and three-dimensionally measured DDs based on enhanced depth imaging optical coherence tomography (EDI-OCT). METHODS The DDs were three-dimensionally measured on EDI-OCT images of optic nerve heads and two-dimensionally measured on near-infrared reflectance fundus images in 90 normal eyes of 90 subjects. Disc rotation around sagittal axis was defined as the angle between maximal DD and vertical axis. Disc rotation around horizontal and vertical axes was defined as cosine of DD on fundus images divided by DD on EDI-OCT images. RESULTS Mean optic disc rotation around vertical axis was 14.4 ± 9.3°, rotation around sagittal axis was 23.0 ± 21.3°, and rotation around horizontal axis was 4.7 ± 6.6°. Horizontal, vertical, minimal, and maximal DDs as measured three-dimensionally were significantly (P < 0.001) higher than those measured two-dimensionally. Difference between three-dimensional and two-dimensional measurement of horizontal DD and vertical DD was associated with axial length (r = 0.38; P < 0.001, and r = 0.23; P = 0.03, respectively). Difference between three-dimensional and two-dimensional measurements was larger (P < 0.001) for horizontal DD (69.6 ± 68.1 μm) than for vertical DD (14.8 ± 25.6 μm). Correspondingly, the ratio of maximal-to-minimal DD (ovality index) was significantly larger (P < 0.001) for two-dimensional (1.33 ± 0.21) than for three-dimensional (1.27 ± 0.16) measurements. CONCLUSIONS Two-dimensional measurement of DDs leads to falsely low results, more for horizontal DD than for vertical DD. The discrepancy between low two-dimensional compared to three-dimensional disc measurements increases with longer axial length. The angle of disc rotation around vertical and horizontal axes can be measured with EDI-OCT imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association of retinal vessel caliber to optic disc and cup diameters.

PURPOSE To investigate whether optic disc size is related to retinal venule and arteriole diameters. METHODS The population of Beaver Dam, Wisconsin, aged 43 to 86 years were invited to participate in a baseline examination from 1988 to 1990. During this examination, photographs, centered on the optic discs, were taken after pupil dilation. Optic discs and cups were measured from stereoscopic...

متن کامل

Retinal vessel diameters and incident open-angle glaucoma and optic disc changes: the Rotterdam study.

PURPOSE It remains unclear whether reduced retinal blood flow and smaller arterioles, reported to exist in patients with open-angle glaucoma (OAG), are a cause or a consequence of ganglion cell loss. We examined whether baseline retinal vessel diameters were related to incident (i)OAG or incident optic disc changes in a population-based sample. METHODS In the prospective population-based Rott...

متن کامل

Optic Nerve Head Change in Non-Arteritic Anterior Ischemic Optic Neuropathy and Its Influence on Visual Outcome

PURPOSE To evaluate changes in cup/disc (C/D) diameter ratios and parapapillary atrophy in patients with non-arteritic anterior ischemic optic neuropathy (NA-AION), using morphometric methods. METHODS The clinical non-interventional study included 157 patients with unilateral or bilateral NA-AION. Optic disc photographs taken from both eyes at the end of follow-up were morphometrically examin...

متن کامل

Pharmacological mydriasis and optic disc examination.

AIM To determine whether pharmacological mydriasis leads to a significant difference in interobserver agreement of optic disc measurement compared with examination without mydriasis. METHOD A cross sectional study was performed with a pair of observers examining the optic disc of two randomised groups of patients, one group before diagnostic mydriasis, and the other afterwards. Horizontal and...

متن کامل

EXTENDED REPORT Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study

Aim: To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). Methods: 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 12  شماره 

صفحات  -

تاریخ انتشار 2015