Quantitative Measurement of Regional Cerebrovascular Reactivity to Acetazolamide Using 123I-N-Isopropyl-p-Iodoamphetamine Autoradiography with SPECT: Validation Study Using H2O with PET

نویسنده

  • Kuniaki Ogasawara
چکیده

A simplified technique using 123I-N-isopropyl-p-iodoamphetamine (123I-IMP) autoradiography (ARG) with SPECT has been proposed recently for quantifying regional cerebral blood flow (rCBF). To validate the accuracy of 123I-IMP-ARG for quantifying regional cerebrovascular reactivity (rCVR) to acetazolamide, we compared rCVR determined using 123I-IMP-ARG with that determined using H2O PET. Methods: Thirty-nine patients with chronic stenoocclusive disease in a unilateral major cerebral artery underwent SPECT and PET studies before and after intravenous administration of acetazolamide. The rCBF images in the 4 conditions in each patient were calculated according to the ARG method. The same standard input function and the same distribution volume of 35 mL/mL were used in the calculation of rCBF images using the 123I-IMP-ARG method at resting state and with acetazolamide challenge. One large cortical region of interest (ROI) for a unilateral middle cerebral artery territory was bilaterally determined on each standardized summed rCBF image. On the basis of the rCBF values in each ROI, rCVR to acetazolamide was calculated as follows: rCVR (%) ([acetazolamide challenge rCBF resting rCBF]/resting rCBF) 100. Results: Significant correlation was observed between rCVR values obtained using 123I-IMP-ARG and H2O PET methods in the 78 ROIs examined in the 39 patients (r 0.820; P 0.0001). When a rCVR lower than the mean 2 SD of values obtained in healthy volunteers (18.4% for 123I-IMPARG and 18.2% for H2O PET) was defined as reduced, and when the H2O PET method was assumed to represent the true determinant of rCVR, 123I-IMP-ARG was 90% sensitive and 92% specific and displayed an 87% positive predictive value for detecting patients with reduced rCVR. Conclusion: These findings demonstrate that 123I-IMP-ARG methods accurately quantify rCVR and can adequately define subgroups of patients with reduced rCVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative measurement of regional cerebrovascular reactivity to acetazolamide using 123I-N-isopropyl-p-iodoamphetamine autoradiography with SPECT: validation study using H2 15O with PET.

UNLABELLED A simplified technique using (123)I-N-isopropyl-p-iodoamphetamine ((123)I-IMP) autoradiography (ARG) with SPECT has been proposed recently for quantifying regional cerebral blood flow (rCBF). To validate the accuracy of (123)I-IMP-ARG for quantifying regional cerebrovascular reactivity (rCVR) to acetazolamide, we compared rCVR determined using (123)I-IMP-ARG with that determined usin...

متن کامل

Detection of misery perfusion with split-dose 123I-iodoamphetamine single-photon emission computed tomography in patients with carotid occlusive diseases.

BACKGROUND AND PURPOSE Patients with carotid occlusive disease and stage 2 cerebral hemodynamic failure, characterized by an increased oxygen extraction fraction (OEF) as measured by positron emission tomography (PET) and otherwise known as misery perfusion, have a high risk of cerebral ischemia and subsequent stroke. In clinical practice, the detection of patients with misery perfusion through...

متن کامل

Qualitative versus quantitative assessment of cerebrovascular reactivity to acetazolamide using iodine-123-N-isopropyl-p-iodoamphetamine SPECT in patients with unilateral major cerebral artery occlusive disease.

BACKGROUND AND PURPOSE Qualitative measurement of regional cerebrovascular reactivity (rCVR) to acetazolamide with single-photon emission CT (SPECT) has been widely used to determine the severity of hemodynamic impairment. We attempted to validate the accuracy of qualitative assessment by using SPECT to detect reduced rCVR compared with rCVR determined quantitatively in patients with unilateral...

متن کامل

Assessment of cerebral hemodynamics in childhood moyamoya disease using a quantitative and a semiquantitative IMP-SPECT study.

BACKGROUND We evaluated the cerebral hemodynamics in childhood moyamoya disease patients before and after surgery to assess both surgical indication and the effect of revascularization using single photon emission computed tomography (SPECT) study with N-isopropyl-p-123I-iodoamphetamine (IMP). We compared results of quantitative and semi-quantitative SPECT studies to determine parameters by the...

متن کامل

Validation studies of iodine-123-iodoamphetamine as a cerebral blood flow tracer using emission tomography.

We studied the radioisotope iodine-123-iodoamphetamine ([123I]IMP) and its performance in single-photon emission computed tomographic (SPECT) studies of cerebral blood flow (CBF). In seven normal volunteers, IMP/SPECT CBF measurements were calculated using a two-compartment model and were compared with the results of CBF measurements utilizing (O15)-H2O and positron emission tomography (PET). C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003