Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography

نویسندگان

  • Christopher A Miller
  • Josephine H Naish
  • Mark P Ainslie
  • Christine Tonge
  • Deborah Tout
  • Parthiban Arumugam
  • Anita Banerji
  • Robin Egdell
  • David Clark
  • Peter J Weale
  • Christopher D Steadman
  • Gerry P McCann
  • Simon G Ray
  • Geoffrey J Parker
  • Matthias Schmitt
چکیده

BACKGROUND Quantitative assessment of myocardial blood flow (MBF) from cardiovascular magnetic resonance (CMR) perfusion images appears to offer advantages over qualitative assessment. Currently however, clinical translation is lacking, at least in part due to considerable disparity in quantification methodology. The aim of this study was to evaluate the effect of common methodological differences in CMR voxel-wise measurement of MBF, using position emission tomography (PET) as external validation. METHODS Eighteen subjects, including 9 with significant coronary artery disease (CAD) and 9 healthy volunteers prospectively underwent perfusion CMR. Comparison was made between MBF quantified using: 1. Calculated contrast agent concentration curves (to correct for signal saturation) versus raw signal intensity curves; 2. Mid-ventricular versus basal-ventricular short-axis arterial input function (AIF) extraction; 3. Three different deconvolution approaches; Fermi function parameterization, truncated singular value decomposition (TSVD) and first-order Tikhonov regularization with b-splines. CAD patients also prospectively underwent rubidium-82 PET (median interval 7 days). RESULTS MBF was significantly higher when calculated using signal intensity compared to contrast agent concentration curves, and when the AIF was extracted from mid- compared to basal-ventricular images. MBF did not differ significantly between Fermi and Tikhonov, or between Fermi and TVSD deconvolution methods although there was a small difference between TSVD and Tikhonov (0.06 mL/min/g). Agreement between all deconvolution methods was high. MBF derived using each CMR deconvolution method showed a significant linear relationship (p<0.001) with PET-derived MBF however each method underestimated MBF compared to PET (by 0.19 to 0.35 mL/min/g). CONCLUSIONS Variations in more complex methodological factors such as deconvolution method have no greater effect on estimated MBF than simple factors such as AIF location and observer variability. Standardization of the quantification process will aid comparison between studies and may help CMR MBF quantification enter clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMR-based quantitative myocardial perfusion: pixel-wise and pound-wise.

p b c uantitative measurement of myocardial perfusion has been a goal of cardiovascular investigators for a number of years. Positron emission tomography (PET) has allowed assessment of myocardial blood flow in absolute value (milliliters per gram per minute) (1) and is accurate at dentifying both flow-limiting epicardial coronary artery isease (CAD) as well as microvascular abnormalities. uali...

متن کامل

Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography.

BACKGROUND It is recognized that the interplay between myocardial ischemia, perfusion, and oxygenation in the setting of coronary artery disease (CAD) is complex and that myocardial oxygenation and perfusion may become dissociated. Blood oxygen level-dependent (BOLD) cardiovascular magnetic resonance (CMR) has the potential to noninvasively measure myocardial oxygenation, whereas positron emiss...

متن کامل

Quantification of regional myocardial oxygenation by magnetic resonance imaging: validation with positron emission tomography.

BACKGROUND A comprehensive evaluation of myocardial ischemia requires measures of both oxygen supply and demand. Positron emission tomography (PET) is currently the gold standard for such evaluations, but its use is limited because of its ionizing radiation, limited availability, and high cost. A cardiac MRI method was developed for assessing myocardial oxygenation. The purpose of this study wa...

متن کامل

Comparison of the quantitative first pass myocardial perfusion MRI with and without prospective slice tracking: comparison between breath-hold and free-breathing condition.

Physiologic motion of the heart is one of the major problems of myocardial blood flow quantification using first pass perfusion-MRI method. To overcome these problems, a perfusion pulse sequence with prospective slice tracking was developed. Cardiac motion was monitored by a navigator directly positioned at heart's basis to overcome no additional underlying model calculations connecting diaphra...

متن کامل

Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects.

Arterial transit time (ATT), a key parameter required to calculate absolute cerebral blood flow in arterial spin labeling (ASL), is subject to much uncertainty. In this study, ASL ATTs were estimated on a per-voxel basis using data measured by both ASL and positron emission tomography in the same subjects. The mean ATT increased by 260 +/- 20 (standard error of the mean) ms when the imaging sla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014