Novel implant design for initial stability of dental implants inserted in fresh extraction sockets: a preliminary study.
نویسندگان
چکیده
OBJECTIVES To evaluate a novel implant design for immediate implantation. This implant presents a specially designed expanded diameter midcrestal "wing" thread, which is aimed to provide added bone contact for greater insertion torque and primary stability. METHODS Mandibular premolars were extracted in 2 mongrel dogs, and immediate dental implants were inserted into the fresh extraction sockets. Implants were evaluated for stability using a resonance frequency analysis device immediately after insertion and after 4 and 8 weeks. Removal torque of 1 randomly selected implant in each hemimandible was measured as well. At 8 weeks, the remaining 6 implants were processed histologically. RESULTS Mean implant stability quotient at implant placement was 64.38 (5.03) and 74.5 (3.08) at 8 weeks. Average removal torque immediately after implant placement was 49.65 (20.3) N.cm and 98.33 (12.34) N.cm at 8 weeks. The mean bone-to-implant contact value at 8 weeks was 38.89% (7.65%). CONCLUSIONS The examined implant with the expanded diameter midcrestal "wing" thread showed good results of resonance frequency analysis and removal torque during the initial healing phase, and as such, it might be used for immediate implantation and loading.
منابع مشابه
Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملFull arch restoration with computer-assisted implant surgery and immediate loading in edentulous ridges with dental fresh extraction sockets. One year results of 10 consecutively treated patients: guided implant surgery and extraction sockets.
There is a growing need for patients to be rehabilitated with a fixed, implant-supported prosthesis immediately after surgery. The present study aims to describe the results of a modified prosthetic and surgical protocol of computer-assisted implant insertion and immediate loading in edentulous jaws with extraction sockets. Ten patients were consecutively treated with a modified computer assist...
متن کاملA 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla
PURPOSE The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. MATERIALS AND METHODS Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mö...
متن کاملTapered, Double-Lead Threads Single Implants Placed in Fresh Extraction Sockets and Healed Sites of the Posterior Jaws: A Multicenter Randomized Controlled Trial with 1 to 3 Years of Follow-Up
PURPOSE To evaluate the survival, success, and complication rates of tapered double-lead threads single implants, placed in fresh extraction sockets and healed sites of the posterior jaws. METHODS The enrolled patients were randomly divided into 2 groups: in the test group (TG), all implants were inserted at the time of tooth extraction; in the control group (CG), all implants were placed 3 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Implant dentistry
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2012