Detection of mercury(II) based on Hg2+ -DNA complexes inducing the aggregation of gold nanoparticles.

نویسندگان

  • Chi-Wei Liu
  • Yi-Ting Hsieh
  • Chih-Ching Huang
  • Zong-Hong Lin
  • Huan-Tsung Chang
چکیده

A DNA-Au NP probe for sensing Hg2+ using the formation of DNA-Hg2+ complexes through thymidine (T)-Hg2+ -T coordination to control the negative charge density of the DNA strands-thereby varying their structures-adsorbed onto Au NPs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of mercury (II) by spectrophotometric method based on self assembly of gold nanoparticles

Due to the binding of the –COO- group with the mercury (II), gold nanoparticlesfunctionalized with glutathione can self-assemble to form a supermolecular network in the HAc-NaAc buffer solution. The aggregation of functionalized gold nanoparticles and mercury (II)caused the shift of maximum absorption peak of the UV-Vis spectrum from 520 nm to 609 nm.Based on this principle, a simple spectropho...

متن کامل

Radial Flow Assay Using Gold Nanoparticles and Rolling Circle Amplification to Detect Mercuric Ions

A novel colorimetric assay employing oligonucleotide-conjugated gold nanoparticle (AuNP probes) and rolling circle amplification (RCA) was developed for simple detection of mercuric ions (Hg2+). The thymine-Hg2+-thymine (T-Hg2+-T) coordination chemistry makes our detection system selective for Hg2+. In the presence of Hg2+, the thymine 12-mer oligonucleotide is unable to act as a primer for RCA...

متن کامل

A Portable Smart-Phone Readout Device for the Detection of Mercury Contamination Based on an Aptamer-Assay Nanosensor

The detection of environmental mercury (Hg) contamination requires complex and expensive instruments and professional technicians. We present a simple, sensitive, and portable Hg2+ detection system based on a smartphone and colorimetric aptamer nanosensor. A smartphone equipped with a light meter app was used to detect, record, and process signals from a smartphone-based microwell reader (MR S-...

متن کامل

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

Highly Selective and Ultrasensitive Turn-On Luminescence Chemosensor for Mercury (II) Determination Based on the Rhodamine 6G Derivative FC1 and Au Nanoparticles

A method for the detection and quantitation of Hg2+ in aqueous samples by fluorescence spectroscopy is presented. It consists of a turn-on sensor developed by coupling Gold nanoparticles (AuNPs) with the rhodamine 6G derivative FC1, in which the response is generated by a mercury-induced ring-opening reaction. The AuNPs were included in order to improve the sensitivity of the method towards the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2008