C-fumarate MRS and diffusion MRI

نویسندگان

  • Lionel Mignion
  • Prasanta Dutta
  • Gary V. Martinez
  • Parastou Foroutan
  • Robert J. Gillies
  • Bénédicte F. Jordan
چکیده

Targeted chemotherapeutic agents often do not result in tumor shrinkage, so new biomarkers that correlate with clinical efficacy are needed. In this study, we investigated noninvasive imaging protocols to monitor responses to sorafenib, a multikinase inhibitor approved for treatment of renal cell and hepatocellular carcinoma. Healthy cells are impermeable to fumarate, so conversion of this metabolite to malate as detected by C-magnetic resonance spectroscopy (MRS) has been suggested as one marker for cell death and treatment response in tumors. Diffusion MRI also has been suggested as a measure of therapy-induced cytotoxic edema because viable cells act as a diffusion barrier in tissue. For these reasons, we assessed sorafenib responses using hyperpolarized C-fumarate, diffusion-weighted MRI (DW-MRI) in a xenograft model of human breast cancer in which daily administration of sorafenib was sufficient to stabilize tumor growth. We detected signals from fumarate and malate following intravenous administration of hyperpolarized fumarate with a progressive increase in the malate-to-fumarate (MA/FA) ratio at days 2 to 5 after sorafenib infusion. The apparent diffusion coefficient (ADC) measured by DW-MRI increased in the treated group consistent with cytotoxic edema. However, the MA/FA ratio was a more sensitive marker of therapeutic response than ADC, with 2.8-fold versus 1.3-fold changes, respectively, by day 5 of drug treatment. Histologic analyses confirmed cell death in the sorafenib-treated cohort. Notably, C-pyruvateto-lactate conversion was not affected by sorafenib in the breast cancer model examined. Our results illustrate how combining hyperpolarized substrates with DW-MRI can allow noninvasive monitoring of targeted therapeutic responses at relatively early times after drug administration. Cancer Res; 74(3); 686–94.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated Systems and Technologies Hyperpolarized C Spectroscopy Detects Early Changes in Tumor Vasculature and Metabolism after VEGF Neutralization

No clinically validated biomarkers exist to image tumor responses to antiangiogenic therapy. Here, we report the utility of hyperpolarized C magnetic resonance spectroscopy (MRS) to detect the early effects of anti-VEGF therapy. In two colorectal cancer xenograft models, displaying differential sensitivity to VEGF blockade, we compared hyperpolarized MRS with measurements of tumor perfusion usi...

متن کامل

Comparison between MRS and DWI in MRI of breast cancer

Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...

متن کامل

In vivo diffusion MRS investigation of non-water molecules in biological tissues.

Diffusion MRS of non-water molecules offers great potential in directly revealing various tissue microstructures and physiology at both cellular and subcellular levels. In brain, 1 H diffusion MRS has been demonstrated as a new tool for probing normal tissue microstructures and their pathological changes. In skeletal muscle, 1 H diffusion MRS could characterize slow and restricted intramyocellu...

متن کامل

Two novel methods for synthesizing poly (propylene fumarate): Technical aspects and role of vacuum and N2 purging effects

Poly (propylene fumarate) (PPF), a linear unsaturated polyester consisting of alternating propylene glycol and fumaric acid units, can be cured in vivo to fill the skeletal defects with minimal surgical intervention. Many different methods have been reported for synthesizing PPF, but none of them gives a clear method. The present paper introduces two new methods in PPF synthesis: Modified reflu...

متن کامل

Detection of tumor response to a vascular disrupting agent by hyperpolarized 13C magnetic resonance spectroscopy.

Nuclear spin hyperpolarization can dramatically increase the sensitivity of the (13)C magnetic resonance experiment, allowing dynamic measurements of the metabolism of hyperpolarized (13)C-labeled substrates in vivo. Here, we report a preclinical study of the response of lymphoma tumors to the vascular disrupting agent (VDA), combretastatin-A4-phosphate (CA4P), as detected by measuring changes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013