AbstractID: 4741 Title: On the Dose Delivered to a Moving Target When Employing Different IMRT Delivery Mechanisms

ثبت نشده
چکیده

ID: 4741 Title: On the Dose Delivered to a Moving Target When Employing Different IMRT Delivery Mechanisms Purpose: To investigate the influence of target motion on dose distributions generated using unmodulated open fields, solid intensity modulator (SIM), Step and Shoot MLC (SMLC) and dynamic MLC (DMLC). Method and Materials: For two lung cancer cases, four treatment plans were generated using Pinnacle 7.9t consisting of an open field, SIM, SMLC and DMLC delivery on a Varian Clinac 600C/D equipped with a 120 leaf Millennium MLC. The coordinates (x, y, z, t) of the 4D motion trace for each of the tumors were determined using 4D-CT from which a 4D motion kernel was generated. For each beam used in the experiment, the beams-eye view tumor motion due to breathing was simulated using a computerized 2D tabletop apparatus. A MAPcheck diode array was incorporated into the apparatus for dose distribution analysis. Each of the four static treatment plans was delivered to the breathing MAPcheck ten times at various points of the breathing cycle. Results: The variation in diode dose readings within the tumor motion envelope was compared for the open field, solid, segmented, and dynamic IMRT deliveries. The open field provided the most uniform dose to the entire set of tumor mimicking diodes followed by SIM, SMLC, and DMLC IMRT, respectively. On an individual diode by diode basis over ten trials, the open field had the smallest average coefficient of variation of 0.122% followed by SIM (0.98%), SMLC (2.22%) and DMLC (3.88%) IMRT delivery, respectively. Conclusion: For the three IMRT delivery methods (SIM, SMLC, and DMLC), SIM consistently provided a more uniform dose to the tumor over many trials. SMLC performed as well as the solid modulators in many cases or was slightly out performed by SIM. DMLC consistently delivered the least uniform dose to the tumor over many trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AbstractID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy

ID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy Purpose: To investigate the computed non-tumor integral dose (NTID) delivered during treatment of prostate cancer with intensity modulated radiotherapy (IMRT) compared to three-dimensional conformal radiotherapy (3DCRT). Low and highenergy photon treatments were also evaluated in this study, as was helical tom...

متن کامل

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

AbstractID: 4975 Title: Modeling Dose Delivery Accuracy of IMRT Head-and-Neck Cancer Treatment

ID: 4975 Title: Modeling Dose Delivery Accuracy of IMRT Head-and-Neck Cancer Treatment Purpose: To evaluate the impact of internal organ variations on IMRT treatments of head-and-neck cancers using different daily alignment techniques. Method and Materials: Eleven head-and-neck cancer patients were imaged twice weekly during their course of treatment (141 CT scans total) using an integrated CT-...

متن کامل

AbstractID: 8181 Title: An algorithm to incorporate leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT

ID: 8181 Title: An algorithm to incorporate leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT Leaf transmission and head scatter are two most important factors that influence IMRT delivery and should be fully taken into account when generating MLC leaf sequences. Significant discrepancies between the desired and delivered intensity profiles could otherwi...

متن کامل

Radiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans

Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006