LTT-MELISA is clinically relevant for detecting and monitoring metal sensitivity.

نویسندگان

  • Elizabeth Valentine-Thon
  • Kurt Müller
  • Gianpaolo Guzzi
  • Sybille Kreisel
  • Peter Ohnsorge
  • Martin Sandkamp
چکیده

OBJECTIVES Chronic low-level metal exposure may result in metal sensitization and undesirable side-effects. The main sources of metal exposure are from the environment or from corrosion of dental metal alloys. Affected patients are routinely diagnosed with the epicutaneous (patch) test. However, such testing may induce false-positive (irritative) reactions and may in itself sensitize or exacerbate symptoms. Alternatively, MELISA (Memory Lymphocyte ImmunoStimulation Assay), an optimized lymphocyte transformation test (LTT), can be used. In this study we analyzed the overall frequency and distribution of metal sensitization among symptomatic, metal-exposed patients. In addition, we determined the reproducibility of the assay and assessed its clinical relevance for detecting and monitoring hypersensitivity to metals. METHODS To analyze the frequency and distribution of metal sensitization, blood from 700 consecutive patients was tested against a total of 26 metals in the validated LTT-MELISA. For reproducibility testing, 391 single metal tests from 63 patients were performed in parallel. Finally, to assess clinical relevance, 14 patients with known metal exposure showing local (dry mouth, Oral Lichen Planus, Burning Mouth Syndrome, eczema) and/or systemic (chronic infections, fatigue, autoimmune disorders, central nervous system disturbances, depression) effects were tested in LTT-MELISA. In 7 cases testing was repeated following removal of the allergy-causing metals or, in 2 additional cases, without therapeutic intervention. RESULTS Of the 700 patients tested, 74.6% responded to >/= 1 metal in LTT-MELISA, with a subgroup of 17.9% responding to >/= 3 metals. Reactivity was most frequent to nickel (68.2%), followed by cadmium (23.7%), gold (17.8%), palladium (12.7%), inorganic mercury (11.4%), molybdenum (10.8%), beryllium (9.7%), titanium dioxide (4.2%), lead (3.7%), and platinum (3.4%). Reproducibility was 94.9%, with most discordant results in a low-positive range. Removal of the alloys or prostheses containing allergenic metals resulted in remarkable clinical improvement correlating with a significant reduction or complete normalization of specific lymphocyte reactivity. In contrast, both LTT-MELISA reactivity and clinical symptoms remained unchanged in follow-up samples from the 2 patients who did not remove the source of metal exposure. CONCLUSION The optimized LTT-MELISA test is a clinically useful and reliable tool for identifying and monitoring metal sensitization in symptomatic metal-exposed individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic use of the lymphocyte transformation test-memory lymphocyte immunostimulation assay in confirming active Lyme borreliosis in clinically and serologically ambiguous cases.

The aim of this study was to carry out an independent evaluation of the proposition that the lymphocyte transformation test-memory lymphocyte immunostimulation assay (LTT-MELISA) may be diagnostically useful in the confirmation of active Lyme borreliosis in clinically and serologically ambiguous cases. Blood samples from 54 patients consecutively presenting to a British center with clinical sus...

متن کامل

A novel lymphocyte transformation test (LTT-MELISA) for Lyme borreliosis.

Diagnosis of active Lyme borreliosis (LB) remains a challenge in clinically ambiguous, serologically indeterminant, and polymerase chain reaction-negative patients. Lymphocyte transformation tests (LTTs) have been applied to detect specific cellular immune reactivity, but their clinical application has been severely hampered by the poorly defined Borrelia antigens and nonstandardized LTT format...

متن کامل

Validity of MELISA for metal sensitivity testing.

OBJECTIVE This study was carried out to evaluate the reproducibility, sensitivity, specificity, and reliability of the MELISA Test for detecting metal sensitivity in patients with clinical symptoms of a type IV hypersensitivity to metal. DESIGN Blood from 250 patients was tested in MELISA against up to 20 different metals in 2 to 3 concentrations. The frequency and distribution of metal react...

متن کامل

The Lymphocyte Transformation Test for Borrelia Detects Active Lyme Borreliosis and Verifies Effective Antibiotic Treatment

Borrelia-specific antibodies are not detectable until several weeks after infection and even if they are present, they are no proof of an active infection. Since the sensitivity of culture and PCR for the diagnosis or exclusion of borreliosis is too low, a method is required that detects an active Borrelia infection as early as possible. For this purpose, a lymphocyte transformation test (LTT) ...

متن کامل

Delayed-Type Hypersensitivity to Metals of Environmental Burden in Patients with Takotsubo Syndrome – Is There a Clinical Relevance?

OBJECTIVE Takotsubo syndrome (TS) is a heart condition characterised by a sudden transient left ventricular dysfunction; its pathophysiology is probably associated with elevated levels of catecholamines but the exact mechanism is not known as yet. Literature and clinical experience suggest that TS affects persons with various comorbidities. This pilot work aims to evaluate the frequency of como...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuro endocrinology letters

دوره 27 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2006