Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.
نویسندگان
چکیده
OBJECTIVES This study sought to identify the incidence and outcome related to inappropriate implantable cardioverter-defibrillator (ICD) shocks, that is, those for nonventricular arrhythmias. BACKGROUND The MADIT (Multicenter Automatic Defibrillator Implantation Trial) II showed that prophylactic ICD implantation improves survival in post-myocardial infarction patients with reduced ejection fraction. Inappropriate ICD shocks are common adverse consequences that may impair quality of life. METHODS Stored ICD electrograms from all shock episodes were adjudicated centrally. An inappropriate shock episode was defined as an episode during which 1 or more inappropriate shocks occurred; another inappropriate ICD episode occurring within 5 min was not counted. Programmed parameters for patients with and without inappropriate shocks were compared. RESULTS One or more inappropriate shocks occurred in 83 (11.5%) of the 719 MADIT II ICD patients. Inappropriate shock episodes constituted 184 of the 590 total shock episodes (31.2%). Smoking, prior atrial fibrillation, diastolic hypertension, and antecedent appropriate shock predicted inappropriate shock occurrence. Atrial fibrillation was the most common trigger for inappropriate shock (44%), followed by supraventricular tachycardia (36%), and then abnormal sensing (20%). The stability detection algorithm was programmed less frequently in patients receiving inappropriate shocks (17% vs. 36%, p = 0.030), whereas other programming parameters did not differ significantly from those without inappropriate shocks. Importantly, patients with inappropriate shocks had a greater likelihood of all-cause mortality in follow-up (hazard ratio 2.29, p = 0.025). CONCLUSIONS Inappropriate ICD shocks occurred commonly in the MADIT II study, and were associated with increased risk of all-cause mortality.
منابع مشابه
Long-Term Survival of Multicenter Automatic Defibrillator Implantation Trial (MADIT) II-Eligible Patients in Taiwan.
BACKGROUND he Multicenter Automatic Defibrillator Implantation Trial (MADIT) II showed that use of a prophylactic implantable cardioverter defibrillator (ICD) improved the survival of patients with poor left ventricular ejection fraction after myocardial infarction. The major concerns about primary ICD prevention in Asian countries are the long-term survival and the incidence of sudden cardiac ...
متن کاملAssociation between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT.
OBJECTIVE The aim of the present study was to assess a possible association between myocardial substrate, implantable cardioverter defibrillator (ICD) shocks, and subsequent mortality. METHODS Within the multicentre automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) population (n = 1790), we investigated the association between myocardial substrate, ICD s...
متن کاملAre the MADIT II criteria for ICD implantation appropriate for Japanese patients?
BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial (MADIT) II investigators concluded that prophylactic use of an implantable cardioverter defibrillator (ICD) improved survival in patients with prior myocardial infarction (MI) and reduced the left ventricular ejection fraction (LVEF). However, it is unclear whether MADIT II criteria for ICD implantation are appropriate for Ja...
متن کاملMortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT).
BACKGROUND The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focu...
متن کاملInappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality.
OBJECTIVES The purpose of this study was to assess the incidence, predictors, and outcome of inappropriate shocks in implantable cardioverter-defibrillator (ICD) patients. BACKGROUND Despite the benefits of ICD therapy, inappropriate defibrillator shocks continue to be a significant drawback. The prognostic importance of inappropriate shocks outside the setting of a clinical trial remains unc...