Facilitated determination of ionized calcium.

نویسندگان

  • P Urban
  • B Buchmann
  • D Scheidegger
چکیده

Using a calcium-containing heparin preparation for anticoagulation, we determined [Ca2+], the mean concentration of ionized calcium, in whole blood of 120 healthy blood-donors to be 1.23 (SD 0.04) mmol/L. Similarly, for 50 intensive-care patients selected without conscious bias, the correlation between [Ca2+] in serum (mean 1.15, SD 0.10 mmol/L) and in whole-blood samples anticoagulated with the same heparin preparation (mean 1.15, SD 0.09 mmol/L) was very good (r = 0.95). Storing samples anaerobically on ice for as long as 2 h did not alter whole-blood [Ca2+]. On the other hand, various concentrations of calcium-free heparin preparations all induced a significant decrease in measured [Ca2+]. By using whole-blood samples, rather than plasma or serum, for [Ca2+] determination with a calcium-selective electrode, repetitive measurements can be made with simple handling procedures, facilitating rapid implementation of appropriate therapeutic measures for critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid Heparin Anticoagulant Produces More Negative Bias in the Determination of Ionized Magnesium than Ionized Calcium

The ionized calcium level in blood is known to be falsely decreased when self-prepared liquid heparin anticoagulant is used, due to dilution and binding effects. The effect of liquid heparin on the determination of ionized magnesium is not as well understood. We compared the effect of liquid sodium heparin on the determination of ionized calcium and magnesium in 44 clinical samples using two ty...

متن کامل

بررسی سطح سرمی کلسیم در مبتلایان به لیکن پلان اروزیو دهانی

Introduction & Objective: Lichen planus is a mucocutaneous disorder with unknown etiology, which may have lots of ethological factors like immunological ones. The disease appears in several clinical forms of which the erosive type is the most important despite its low preva-lence. This is because of the signs like pain, irritation and risk of malignancy. In spite of us-ing different drugs, ther...

متن کامل

Determination of ionized calcium in serum that has been exposed to air.

We examined changes in ionized calcium concentration in serum after its exposure to air. Samples with total protein concentrations ranging from 50 to 90 g/liter were equilibrated with CO2 in nitrogen (5/95, by vol) or CO2 alone, to produce pH values of 7.0 to 8.0. Ionized calcium was then measured with an Orion flow-through electrode system. Curves relating pH and ionized calcium concentration ...

متن کامل

Ionized calcium: its significance and clinical usefulness.

Maintenance of normal blood levels of ionized calcium (Ca2+) plays an important role in the management of the critically ill patient. Therefore, Ca2+ should be collected properly and measured reliably. The sound analytical performance of today's Ca2+ analyzers using ion-selective electrode technology have made measurements accurate and precise. The introduction of this technology allows rapid a...

متن کامل

مقایسه میزان سرمی کلسیم کل و یونیزه در خانم‌های حامله مبتلا به پره‌اکلامپسی و خانم‌های با حاملگی طبیعی

  The Comparison of Total and Ionised Serum Calcium Level in Preeclamptic Pregnant Women and the Women with Normal Pregnancy     Z. Salari MD1*, N. Eftekhari MD2     1- Assistan Professor, Dept of Gynecology, University of Medical Sciences, Kerman, Iran   2- Associated Professor, Dept of Gynecology, University of Medical Sciences, Kerman, Iran     Background: Preeclampsia remains one of the imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 1985