Diastolic Backward-Traveling Decompression (Suction) Wave Correlates With Simultaneously Acquired Indices of Diastolic Function and Is Reduced in Left Ventricular Stunning.
نویسندگان
چکیده
BACKGROUND Wave intensity analysis can distinguish proximal (propulsion) and distal (suction) influences on coronary blood flow and is purported to reflect myocardial performance and microvascular function. Quantifying the amplitude of the peak, backwards expansion wave (BEW) may have clinical utility. However, simultaneously acquired wave intensity analysis and left ventricular (LV) pressure-volume loop data, confirming the origin and effect of myocardial function on the BEW in humans, have not been previously reported. METHODS AND RESULTS Patients with single-vessel left anterior descending coronary disease and normal ventricular function (n=13) were recruited prospectively. We simultaneously measured LV function with a conductance catheter and derived wave intensity analysis using a pressure-low velocity guidewire at baseline and again 30 minutes after a 1-minute coronary balloon occlusion. The peak BEW correlated with the indices of diastolic LV function: LV dP/dtmin (rs=-0.59; P=0.002) and τ (rs=-0.59; P=0.002), but not with systolic function. In 12 patients with paired measurements 30 minutes post balloon occlusion, LV dP/dtmax decreased from 1437.1±163.9 to 1299.4±152.9 mm Hg/s (median difference, -110.4 [-183.3 to -70.4]; P=0.015) and τ increased from 48.3±7.4 to 52.4±7.9 ms (difference, 4.1 [1.3-6.9]; P=0.01), but basal average peak coronary flow velocity was unchanged, indicating LV stunning post balloon occlusion. However, the peak BEW amplitude decreased from -9.95±5.45 W·m(-2)/s(2)×10(5) to -7.52±5.00 W·m(-2)/s(2)×10(5) (difference 2.43×10(5) [0.20×10(5) to 4.67×10(5); P=0.04]). CONCLUSIONS Peak BEW assessed by coronary wave intensity analysis correlates with invasive indices of LV diastolic function and mirrors changes in LV diastolic function confirming the origin of the suction wave. This may have implications for physiological lesion assessment after percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.isrctn.org. Unique identifier: ISRCTN42864201.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملImprovement in coronary blood flow velocity with acute biventricular pacing is predominantly due to an increase in a diastolic backward-travelling decompression (suction) wave.
BACKGROUND Normal coronary blood flow is principally determined by a backward-traveling decompression (suction) wave in diastole. Dyssynchronous chronic heart failure may attenuate suction, because regional relaxation and contraction overlap in timing. We hypothesized that biventricular pacing, by restoring left ventricular (LV) synchronization and improving LV relaxation, might increase this s...
متن کاملEvidence of a dominant backward-propagating "suction" wave responsible for diastolic coronary filling in humans, attenuated in left ventricular hypertrophy.
BACKGROUND Coronary blood flow peaks in diastole when aortic blood pressure has fallen. Current models fail to completely explain this phenomenon. We present a new approach-using wave intensity analysis-to explain this phenomenon in normal subjects and to evaluate the effects of left ventricular hypertrophy (LVH). METHOD AND RESULTS We measured simultaneous pressure and Doppler velocity with ...
متن کاملLEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION
In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...
متن کاملبررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی
Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 9 9 شماره
صفحات -
تاریخ انتشار 2016