Comparison of dose distributions hippocampus in high grade gliomas irradiation with linac-based imrt and volumetric arc therapy: a dosimetric study
نویسندگان
چکیده
The aim of this study was to assess the feasibility of sparing contralateral hippocampus during partial brain radiotherapy in high grade gliomas. 20 previously treated patients were replanned to 60 Gy in 30 fractions with sparing intensity-modulated radiotherapy (IMRT) and volumetric modulated arctherapy (VMAT) using the following planning objectives: 100 % of PTV covered by 95% isodose without violating organs at risk (OAR) and hot spot dose constraints. For each, standard intensity-modulated radiotherapy (IMRT) plans were generated, as well as sparing IMRT and VMAT plans which spared contralateral (hemispheric cases) hippocampus. When the three plans were compared, there was equivalent PTV coverage, homogeneity, and conformality. Sparing IMRT significantly reduced maximum, mean, V20, V30 and V40 hippocampus doses compared with standart IMRT and VMAT (p < 0.05). VMAT significantly reduced maximum left lens and mean eye doses compared with standart IMRT and sparing IMRT (p < 0.05). Brainstem, chiasm, left and right optic nerves, right eyes and lens doses were similar. VMAT significantly reduced monitor units compared with standart IMRT and sparing IMRT (p < 0.05). It is possible to spare contralateral hippocampus during PBRT for high grade gliomas using IMRT. This approach may reduce late cognitive sequelae of cranial radiotherapy.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملThe Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کاملComparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...
متن کاملDosimetric comparison of volumetric modulated arc therapy (VMAT), step and shoot and sliding window IMRT for prostate cancer Introduction: The goal of delivering higher uniform doses to the planning
ID: 17554 Title: Dosimetric comparison of volumetric modulated arc therapy (VMAT), step and shoot and sliding window IMRT for prostate cancer 1 : Baltas D, Kolotas C, Geramani K, et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys 40, 515-524 (1998). 2 : van’t Riet A, Mak AC, Moerland MA, et al. A conformation number ...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کامل