Protocol for electrophysiological monitoring of carotid endarterectomies
نویسندگان
چکیده
Near zero stroke rates can be achieved in carotid endarterectomy (CEA) surgery with selective shunting and electrophysiological neuromonitoring. though false negative rates as high as 40% have been reported. We sought to determine if improved training for interpretation of the monitoring signals can advance the efficacy of selective shunting with electrophysiological monitoring across multiple centers, and determine if other factors could contribute to the differences in reports. Processed and raw beta band (12.5-30 Hz) electroencephalogram (EEG) and median and tibial nerve somatosensory evoked potentials (SSEP) were monitored in 668 CEA cases at six surgical centers. A decrease in amplitude of 50% or more in any EEG or SSEP channel was the criteria for shunting or initiating a neuroprotective protocol. A reduction of 50% or greater in the beta band of the EEG or amplitude of the SSEP was observed in 150 cases. No patient showed signs of a cerebral infarct after surgery. Selective shunting based on EEG and SSEP monitoring can reduce CEA intraoperative stroke rate to a near zero level if trained personnel adopted standardized protocols. We also found that the rapid administration of a protective stroke protocol by attending anesthesiologists was an important aspect of this success rate.
منابع مشابه
Results of Electroencephalographic Monitoring During 367 Carotid Endarterectomies
Three hundred sixty-seven carotid endarterectomies were monitored using routine electroencephalographic (EEG) techniques. In 9.8%, changes in the EEG followed clamping of the internal carotid artery and could roughly be grouped into 6 patterns. The most common (47%) was rapid unilateral or bilateral attenuation of background anesthetic-induced fast EEG activity. Conclusions drawn from studies o...
متن کاملResults of Electroencephalographic Monitoring During 367 Carotid Endarterectomies
Three hundred sixty-seven carotid endarterectomies were monitored using routine electroencephalographic (EEG) techniques. In 9.8%, changes in the EEG followed clamping of the internal carotid artery and could roughly be grouped into 6 patterns. The most common (47%) was rapid unilateral or bilateral attenuation of background anesthetic-induced fast EEG activity. Conclusions drawn from studies o...
متن کاملResults of electroencephalographic monitoring during 367 carotid endarterectomies. Use of a dedicated minicomputer.
Three hundred sixty-seven carotid endarterectomies were monitored using routine electroencephalographic (EEG) techniques. In 9.8%, changes in the EEG followed clamping of the internal carotid artery and could roughly be grouped into 6 patterns. The most common (47%) was rapid unilateral or bilateral attenuation of background anesthetic-induced fast EEG activity. Conclusions drawn from studies o...
متن کاملSite and pathogenesis of infarcts associated with carotid endarterectomy.
We analyzed perioperative strokes in 658 carotid endarterectomies with the purpose of explaining the pathogenesis from the morphologic aspect of the infarct on cerebral computed tomograms. All endarterectomies were performed with continuous electroencephalographic monitoring. Of the 42 ischemic strokes (6.4% of all endarterectomies), 34 could be studied. Seven infarcts were hemodynamically indu...
متن کاملVascular endoscopy --- an adjunct to carotid surgery.
Technical advances in optical instrumentation have made vascular endoscopy a potential method for intraoperative evaluation of carotid endarterectomy. A prospective protocol was designed to evaluate the efficacy and practicality of this technique using the Hopkins Optical System in 35 carotid endarterectomies. The external carotid artery was examined after completion of the endarterectomy. The ...