Impedance plethysmography: the relationship between venous filling and sensitivity and specificity for proximal vein thrombosis.
نویسندگان
چکیده
We investigated the hypothesis that the diagnostic accuracy of impedance plethysmography (IPG) for thrombosis of the popliteal or more proximal veins increases with enhanced venous filling. Venous filling was increased by prolonging cuff occlusion and by sequential testing. IPG and vengography were performed on 169 legs with and 317 legs without proximal vein thrombosis. The sensitivity and specificity of IPG rose significantly with increased venous filling. Changes in venous filling were associated with corresponding changes in emptying in normal legs, but not those with proximal vein thrombosis, so that the regression lines relating venous filling and emptying in normal and abnormal legs diverged significantly (P less than 0.001). If the IPG sequence had been terminated after only a single 45 second occlusion time test, sensitivity would have deteriorated by 10% and specificity by 20%. These observations indicate that the accuracy of IPG can be significantly enhanced if optimal venous filling is obtained.
منابع مشابه
Diagnosis of Venous Thrombosis
Impedance plethysmography using the cuff technique has been compared with venography in 346 consecutive patients with suspected venous thromboembolism. The limbs were classified according to the venographic results as no thrombosis, proximal (popliteal, femoral, or iliac) vein thrombosis, and calf thrombosis. A discriminant analysis was performed. The impedance plethysmographic result was norma...
متن کاملImpedance plethysmography. A screening procedure to detect deep-vein thrombosis.
Impedance plethysmography has great potential in the non-invasive detection of dangerous iliofemoral thrombosis. It was used to examine 198 patients undergoing total hip replacement for evidence of proximal venous segment thrombosis. There were 13 abnormal results, and subsequent venography in 12 of these revealed a false-positive rate of 4.0%; there was one false-negative result giving a sensi...
متن کاملA novel and rapid whole-blood assay for D-dimer in patients with clinically suspected deep vein thrombosis.
BACKGROUND The clinical utility of using a novel whole blood assay for D-dimer (SimpliRED), alone or in combination with impedance plethysmography (IPG), was investigated in a two-center, prospective cohort study of 214 consecutive patients with clinically suspected deep vein thrombosis (DVT). METHODS AND RESULTS All patients underwent the SimpliRED D-dimer assay, contrast venography, and IPG...
متن کاملPlasma and urine beta-thromboglobulin concentration in patients with deep vein thrombosis.
Plasma and urine beta-thromboglobulin (BTG) were measured in 52 patients with established deep vein thrombosis (DVT) and in 100 patients with clinically suspected DVT but with a negative venogram. Both plasma BTG (geometric mean 54: 95% range 12--239 ng/ml) and urine BTG (0.25; 0.03--3.1 ng/ml) were significantly elevated (p less than 0.005) in patients with DVT compared to symptomatic patients...
متن کاملRadionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography.
Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. A range of normal values was def...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 58 5 شماره
صفحات -
تاریخ انتشار 1978