Perfusion quantification using Gaussian process deconvolution.
نویسندگان
چکیده
The quantification of perfusion using dynamic susceptibility contrast MRI (DSC-MRI) requires deconvolution to obtain the residual impulse response function (IRF). In this work, a method using the Gaussian process for deconvolution (GPD) is proposed. The fact that the IRF is smooth is incorporated as a constraint in the method. The GPD method, which automatically estimates the noise level in each voxel, has the advantage that model parameters are optimized automatically. The GPD is compared to singular value decomposition (SVD) using a common threshold for the singular values, and to SVD using a threshold optimized according to the noise level in each voxel. The comparison is carried out using artificial data as well as data from healthy volunteers. It is shown that GPD is comparable to SVD with a variable optimized threshold when determining the maximum of the IRF, which is directly related to the perfusion. GPD provides a better estimate of the entire IRF. As the signal-to-noise ratio (SNR) increases or the time resolution of the measurements increases, GPD is shown to be superior to SVD. This is also found for large distribution volumes.
منابع مشابه
Fully automated pixel-wise myocardial blood flow quantification with first-pass perfusion CMR
Methods Rest and adenosine stress perfusion imaging was performed on 17 normal volunteers. A saturation recovery SSFP dual-sequence technique was used to acquire three myocardial slices and an arterial input function (AIF) image series. A proton-density weighted image was acquired at the beginning of each series. Fully quantitative perfusion pixel maps were generated by an automated processing ...
متن کاملModelling Parameter Role on Accuracy of Cardiac Perfusion Quantification
Cardiovascular magnetic resonance (CMR) perfusion data are suitable for quantitative measurement of myocardial blood flow. The goal of perfusionCMR postprocessing is to recover tissue impulse-response from observed signalintensity curves. While several deconvolution techniques are available for this purpose, all of them use models with varying parameters for the representation of the impulse-re...
متن کاملVoxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography
BACKGROUND Quantitative assessment of myocardial blood flow (MBF) from cardiovascular magnetic resonance (CMR) perfusion images appears to offer advantages over qualitative assessment. Currently however, clinical translation is lacking, at least in part due to considerable disparity in quantification methodology. The aim of this study was to evaluate the effect of common methodological differen...
متن کاملPerfusion quantification of the whole lung using singular value decomposition with optimized threshold
F. Risse, C. Fink, S. Ley, H-U. Kauczor, L. R. Schad Department of Medical Physics in Radiology, Deutsches Krebsforschungszentrum, Heidelberg, Germany, Department of Radiology, Deutsches Krebsforschungszentrum, Heidelberg, Germany Introduction Contrast-enhanced 3D MRI offers the capability to assess lung perfusion non-invasively and without radiation exposure [1]. Recently, parallel imaging tec...
متن کاملParallel perfusion imaging processing using GPGPU
BACKGROUND AND PURPOSE The objective of brain perfusion quantification is to generate parametric maps of relevant hemodynamic quantities such as cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) that can be used in diagnosis of acute stroke. These calculations involve deconvolution operations that can be very computationally expensive when using local Arterial I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 48 2 شماره
صفحات -
تاریخ انتشار 2002