Global Surface Net-Radiation at 5 km from MODIS Terra
نویسندگان
چکیده
Reliable and fine resolution estimates of surface net-radiation are required for estimating latent and sensible heat fluxes between the land surface and the atmosphere. However, currently, fine resolution estimates of net-radiation are not available and consequently it is challenging to develop multi-year estimates of evapotranspiration at scales that can capture land surface heterogeneity and are relevant for policy and decision-making. We developed and evaluated a global net-radiation product at 5 km and 8-day resolution by combining mutually consistent atmosphere and land data from the Moderate Resolution Imaging Spectroradiometer (MODIS) on board Terra. Comparison with net-radiation measurements from 154 globally distributed sites (414 site-years) from the FLUXNET and Surface Radiation budget network (SURFRAD) showed that the net-radiation product agreed well with measurements across seasons and climate types in the extratropics (Wilmott’s index ranged from 0.74 for boreal to 0.63 for Mediterranean sites). Mean absolute deviation between the MODIS and measured net-radiation ranged from 38.0 ± 1.8 W·m−2 in boreal to 72.0 ± 4.1 W·m−2 in the tropical climates. The mean bias was small and constituted only 11%, 0.7%, 8.4%, 4.2%, 13.3%, and 5.4% of the mean absolute error in daytime net-radiation in boreal, Mediterranean, temperate-continental, Remote Sens. 2016, 8, 739; doi:10.3390/rs8090739 www.mdpi.com/journal/remotesensing Remote Sens. 2016, 8, 739 2 of 20 temperate, semi-arid, and tropical climate, respectively. To assess the accuracy of the broader spatiotemporal patterns, we upscaled error-quantified MODIS net-radiation and compared it with the net-radiation estimates from the coarse spatial (1◦ × 1◦) but high temporal resolution gridded net-radiation product from the Clouds and Earth’s Radiant Energy System (CERES). Our estimates agreed closely with the net-radiation estimates from the CERES. Difference between the two was less than 10 W·m−2 in 94% of the total land area. MODIS net-radiation product will be a valuable resource for the science community studying turbulent fluxes and energy budget at the Earth’s surface.
منابع مشابه
Evaluation of land surface radiation balance derived from moderate resolution imaging spectroradiometer (MODIS) over complex terrain and heterogeneous landscape on clear sky days
Many studies on land surface radiation balances have relied on geostationary satellites. These satellites have provided data with high temporal resolution (less than 3 h); however, the spatial resolution was too coarse (20–250 km scale) to investigate local-scale land surface radiation balances. Moderate resolution imaging spectroradiometer (MODIS) – onboard both the Terra and Aqua satellites –...
متن کاملAdvances in Earth Radiation Budget Observations from Ceres Terra
The goal of the Clouds and the Earth's Radiant Energy System (CERES) project is to provide a long-term record of radiation budget at the top-of-atmosphere (TOA), within the atmosphere, and at the surface with consistent cloud and aerosol properties at climate accuracy [1]. CERES consists of an integrated instrument-algorithm-validation science team that provides development of higher-level prod...
متن کاملValidation of JAXA/MODIS Sea Surface Temperature in Water around Taiwan Using the Terra and Aqua Satellites
The research vessel-based Conductivity Temperature Depth profiler (CTD) provides underwater measurements of the bulk sea surface temperature (SST) at the depths of shallower than 5 m. The CTD observations of the seas around Taiwan provide useful data for comparison with SST of MODIS (Moderate Resolution Imaging Spectroradiometers) aboard Aqua and Terra satellites archived by JAXA (Japan Aerospa...
متن کاملImpact of day/night time land surface temperature in soil moisture disaggregation algorithms
Since its launch in 2009, the ESA’s SMOS mission is providing global soil moisture (SM) maps at ~40 km, using the first L-band microwave radiometer on space. Its spatial resolution meets the needs of global applications, but prevents the use of the data in regional or local applications, which require higher spatial resolutions (~1-10 km). SM disaggregation algorithms based generally on the lan...
متن کاملWater vapor retrievals using Moderate Resolution Imaging Spectroradiometer (MODIS) near-infrared channels
[1] At present, two Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on board the NASA Terra and Aqua Spacecraft platforms are operational for global remote sensing of the land, ocean, and atmosphere. In this paper, we describe an algorithm for water vapor derivations using several MODIS near-IR channels. The derivations are made over areas that have reflective surfaces in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Remote Sensing
دوره 8 شماره
صفحات -
تاریخ انتشار 2016