Effects of Rotational Motion in Robotic Needle Insertion
نویسندگان
چکیده
BACKGROUND Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. OBJECTIVE In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. METHODS Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. RESULTS Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. CONCLUSION Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results.
منابع مشابه
Effects of Rotational Motion in Robotic Needle Insertion
Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...
متن کاملRobotic needle insertion: effects of friction and needle geometry
Two experiments were performed to determine the effects of friction and needle geometry during robotic needle insertion into soft tissues. In Experiment I, friction forces along the instrument axis were characterized during needle insertion into bovine liver under CT fluoroscopic imaging. Because the relative velocity of the tissue and needle affect viscous and Coulomb friction, the needle inse...
متن کاملAutomatic formulation of falling multiple flexible-link robotic manipulators using 3×3 rotational matrices
In this paper, the effect of normal impact on the mathematical modeling of flexible multiple links is investigated. The response of such a system can be fully determined by two distinct solution procedures. Highly nonlinear differential equations are exploited to model the falling phase of the system prior to normal impact; and algebraic equations are used to model the normal collision of this ...
متن کاملVirtual Remote Center of Motion Control for Needle Placement Robots
OBJECTIVE We present an algorithm that enables percutaneous needle-placement procedures to be performed with unencoded, unregistered, minimally calibrated robots while removing the constraint of placing the needle tip on a mechanically enforced Remote Center of Motion (RCM). MATERIALS AND METHODS The algorithm requires only online tracking of the surgical tool and a five-degree-of-freedom (5-...
متن کاملMacroscopic and microscopic observations of needle insertion into gels.
Needle insertion into soft tissue is one of the most common medical interventions. This study provides macroscopic and microscopic observations of needle-gel interactions. A gelatin mixture is used as a soft-tissue simulant. For the macroscopic studies, system parameters, such as insertion velocity, needle diameter, gel elasticity, needle tip shape (including bevel angle) and insertion motion p...
متن کامل