Safety of MRI in patients with implanted deep brain stimulation devices.

نویسندگان

  • Michele Tagliati
  • Joseph Jankovic
  • Fernando Pagan
  • Frandy Susatia
  • Ioannis U Isaias
  • Michael S Okun
چکیده

OBJECTIVE To survey the safety of MRI in PD patients implanted with DBS devices. BACKGROUND MRI in patients with DBS implants is useful to confirm electrode placement, optimize programming and investigating complications. However, several medical centers do not perform MRI studies in DBS patients because of safety concerns. The safety profile of MRI in DBS patients has not been documented in large clinical series. METHODS 42 NPF Centers of Excellence (COEs) were asked to complete a questionnaire on MRI use and DBS. RESULTS Investigators from 40 of 42 (95%) NPF COEs completed the survey and 23 (58%) reported that they were currently performing brain MRI in DBS patients, while 3 (7.5%) had done it in the past. The 17 COEs currently not performing post-operative MRI for DBS listed the following reasons: 1) industry guidelines and/or warnings (53%); 2) decision deferred to outside department (29%); 3) liability/risk/safety (18%); 4) no active DBS program (18%); 5) no available MRI (12%); and 6) insurance and reimbursement concerns (6%). A total of 3304 PD patients with one or more DBS leads had a brain MRI scan, and 177 DBS patients had MRI of other body regions. In one case MRI was associated with an IPG failure without neurological sequelae after IPG replacement. No other complications were reported. CONCLUSIONS these data provide evidence for a favorable risk/benefit ratio for brain MRI in patients with DBS implants. Further studies will need to address whether a re-assessment of more restrictive recommendations (i.e. very low SAR values) may be warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical safety of brain magnetic resonance imaging with implanted deep brain stimulation hardware: large case series and review of the literature.

BACKGROUND Over 75,000 patients have undergone deep brain stimulation (DBS) procedures worldwide. Magnetic resonance imaging (MRI) is an important clinical and research tool in analyzing electrode location, documenting postoperative complications, and investigating novel symptoms in DBS patients. Functional MRI may shed light on the mechanism of action of DBS. MRI safety in DBS patients is ther...

متن کامل

MRI-related heating near deep brain stimulation electrodes: more data are needed.

Magnetic resonance imaging (MRI) of patients with implanted deep brain stimulation (DBS) devices poses a challenge for healthcare providers. As a consequence of safety concerns about magnetic field interactions with the device, induced electrical currents and thermal damage due to radiofrequency heating, a number of stringent guidelines have been proposed by the device manufacturer. Very few de...

متن کامل

Relationship of the P Angle with Stereotactic Arc in Intraoperative Outcome of Patients with Parkinson’s Disease Undergoing Deep Brain Stimulation

Background & Aim: DBS (deep brain stimulation) is a new and successful technique in treatment of symptoms of Parkinsonism especially after drug resistance. Research in this field is mostly designed for evolution of this technique. The present study aimed at evaluating the relationship between the angle formed in midsagittal and STN (sub-thalamic nucleus) axis line and recording l...

متن کامل

P144: Review of Deep Brain Stimulation Target Areas in Patients with Obsessive-Compulsive Disorder

Obsessive-compulsive disorder (OCD) is a psychiatric disorder manifested by thoughts and impulses that produce anxiety and result in patients performing repetitive rituals. Treatment generally consists of cognitive behavioral intervention and serotonin reuptake inhibitors. Up to 40% of patients will have functional impairment that significantly affects their quality of life. In the late 1990’s,...

متن کامل

Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series.

Magnetic resonance imaging (MRI) is a commonly used and important imaging modality to evaluate lead location and rule out complications after deep brain stimulation (DBS) surgery. Recent safety concerns have prompted new safety recommendations for the use of MRI in these patients, including a new recommendation to limit the specific absorption rate (SAR) of the MRI sequences used to less than 0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 47 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2009